CRU
R T X 4 1 0 / 6 1 0 / 8 0 1 - I R U s e r M a n u a l A 9 - 4 6 8 - 0 0 0 5 R E V 1 . 0
- 42 -
Info
Web Logout
<username logout from <IP> via Web UI
Info
Log clear
All event logs are cleared
Warning
Send mail fail
Failed to send event to <email>
LVM Events
Level
Type
Description
Info
RG create OK
RG <name> has been created
Info
RG create fail
Failed to create RG <name>
Info
RG delete
RG <name> has been deleted
Info
RG rename
RG <name> has been renamed as <name>
Info
VD create OK
VD <name> has been created.
Info
VD create fail
Failed to create VD <name>
Info
VD delete
VD <name> has been deleted
Info
VD rename
The name of VD <name> has been renamed to <name>
Info
VD read only
Cache policy of VD <name> has been set as read only
Info
VD write back
Cache policy of VD <name> has been set as write-back
Info
VD write through
Cache policy of VD <name> has been set as write-through
Info
VD extend
Size of VD <name> extends
Info
VD attach LUN OK
VD <name> has been LUN-attached
Info
VD attach LUN fail
Failed to attach LUN to VD <name>
Info
VD detach LUN OK
VD <name> has been detached
Info
VD detach LUN fail
Failed to detach LUN from bus <number> SCSI ID
<number>, LUN <number>
Info
VD init started
VD <name> starts initialization
Info
VD init finished
VD <name> completes initialization
Warning
VD init failed
Failed to complete initialization of VD <name>
Info
VD rebuild started
VD <name> starts rebuilding
Info
VD rebuild finished
VD <name> completes rebuilding
Warning
VD rebuild failed
Failed to complete rebuild of VD <name>
Info
VD migrate started
VD <name> starts migration
Info
VD migrate finished
VD <name> completes migration
Error
VD migrate failed
Failed to complete migration of VD <name>
Info
VD scrub started
Parity checking on VD <name> starts
Info
VD scrub finished
Parity checking on VD <name> completes with <address>
parity/data inconsistency found
Info
VD scrub aborted
Parity checking on VD <name> stops with <address>
parity/data inconsistency found
Info
RG migrate started
RG <name> starts migration
Info
RG migrate finished
RG <name> completes migration
Info
RG move started
RG <name> starts move
Info
RG move finished
RG <name> completes move
Info
VD move started
VD <name> starts move
Info
VD move finished
VD <name> completes move
Error
VD move failed
Failed to complete move of VD <name>
Info
RG activated
RG <name> has been manually activated
Info
RG deactivated
RG <name> has been manually deactivated
Info
VD rewrite started
Rewrite at LBA <address> of VD <name> starts
Info
VD rewrite finished
Rewrite at LBA <address> of VD <name> completes
Warning
VD rewrite failed
Rewrite at LBA <address> of VD <name> failed
Warning
RG degraded
RG <name> is in degraded mode
Warning
VD degraded
VD <name> is in degraded mode
Error
RG failed
RG <name> is failed