SAM52 User's Manual v2.3
Introduction
•
3
Cash Register Settings
To communicate with your
Samsung ER-5200M Series
ECR, you must set the RS232C port
for the PC function.
Setting the RS232C Port Options
You must select ‘PC’ as the device that is attached to the RS-232C communications port.
1.
Turn the control lock to the
S
position.
2.
Enter
8 0
(enter
8 1
to program the second port) and press the
SBTL
key.
3.
Enter
5
and press the
X/TIME
key. (Refer to the chart RS-232C option chart that
follows.)
4.
Enter
1
(the value for PC) and press the
CASH
key.
5.
Press
CASH
to exit the program.
RS-232 Option Chart
Address
Option
Value
Selection
0
9600 BPS
1
1200 BPS
2
2400 BPS
3
4800 BPS
1
Baud Rate
4
19200 BPS
0
NONE
1
ODD
2
Parity
2
EVEN
0
8 BITS
3
Data Bits
1
7 BITS
0
1 BIT
4
Stop Bits
1
2 BIT
0
NONE
1
PC
2
SCALE
4
Receipt Printer
5
Not used
7
COIN
9
Pole Display
5
Device Function
10
PDC (Requires V6.1 or later)
6
Initial Feeding Line KP
0 - 20
7
End Feeding Line KP
0 - 20
8
Initial Feeding Line Slip
0 - 20
9
Print Line On Guest Check
0 - 50
Repeat for another
Index
XTIME
OPTION
SBTL
0/1
8
CASH
VALUE
CASH