INSTALLATION & OPERATION MANUAL 10124 REV 0 (03/21)
PAGE
16
OF 20
G
as
F
ired
S
teamers
T
ROUBLESHOOTING
T
ROUBLESHOOTING
B
urners
N
o
N
ot
C
ome
O
n
1. Gas supply to unit is “OFF”.
2. Power Switch is not turned “ON”.
3. Steam generator probe not sensing the water level, will not call for ignition.
4. Ignitor not functioning.
5. Gas combination supply valve not opening.
B
urners
P
roduce
C
arbon
D
eposits
1. Wrong orifice size.
2. Wrong gas supply.
3. Incorrect pressure at supply.
4. Not enough primary air.
W
ater
F
lows into
C
ooking
C
ompartment
Probes not sensing water, thereby not operating fill solenoid.
1. Scale build-up on operating probe inside the generator.
2. Water fill solenoid valve is not closed. Check for scale or foreign particles lodged in diaphragm or core tube of valve.
These problems are an indication of severe harmful water conditions which should be corrected immediately to avoid
damage to the components and performance of the steamer.
D
oor
L
eaks
1. Check for damage to door gasket.
2. Clogged compartment drain or plumbing.
W
ater
A
ccumulates in the
C
ompartment
1. Compartment drain clogged.
W
ater
F
lows into
D
rain
D
uring
S
hut
D
own
1. Condensate valve does not close. Check thermostatic cooling valve body for foreign particles or damage.
2. Water fill solenoid valve is not closed. Check for scale or foreign particles lodged in diaphragm or core tube of valve.
W
ater
N
ot
B
eing
S
upplied to
S
team
G
enerator
1. Water supply is “OFF”.
2. Supply water pressure too low.
3. Defective water fill solenoid valve.
4. Shortage of circuit between probes and body.
5. Check that drain solenoid is closed.