INSTALLATION & OPERATION MANUAL 10124 REV 0 (03/21)
PAGE
4
OF 20
G
as
F
ired
S
teamers
S
ERVICE
C
ONNECTIONS
S
ERVICE
C
ONNECTIONS
SPECIFICATIONS
GAS CHARACTERISTICS
SERVICE CONNECTIONS
– ELECTRICAL CONNECTION: Unless otherwise specified, Electrical Connection to be 120 Volts, 6.
Hertz single phase with ground Furnished with 6 foot cord with 3 prong plug. Maxximum 4.0 amps.
– DRAIN: 2” (51 mm) IPS piped to open floor drain. No solid connection.
– GAS CONNECTION: 3/4” IPS supply line required.
– CONDENSATE COLD WATER: 3/8” O.D. tubing at 25-50 PSI (170-345 kPa)
– BOILER FEED WATER: 3/8” O.D. tubingat 25-50 PSI (170-345 kPa).
WATER QUALITY STATEMENT
Water is the essential ingredient in steam equipment, water quality is the major factor affecting the performance of your appliance. Crown Steam Group offers a
Comprehensive Water Treatment System which exceeds our minimum water requirements. Proof of installation and proper cartridges replacement is required for
warranty coverage. Water supply to Crown Steam Group steamers must be within these guidelines.
Water which does not meet these standards should be treated with the installation of Middleby’s Water Treatment System. Call 919-762-1000 if you have
questions concerning your water meeting these parameters.
*Failure or malfunction of this appliance due to poor water quality is not covered under warranty.
Reference www.crownsteamgroup.com for complete warranty details and instructions.
M
odel
G
as
s
upply
p
ressure
BTu/Hr.
k
W/Hr.
N
aTural
p
ropaNe
GSX-7HE
140,000
41
6”-14” (152-356mm)
12”-14” (305-356mm)
GSX-10HE
190,000
56
6”-14” (152-356mm)
12”-14” (305-356mm)
GSX-16HE
190,000
56
6”-14” (152-356mm)
12”-14” (305-356mm)
Model
Compartments
Capacity
s
HippiNG
WT
C
learaNCe
GSX-7HE
2
1-7 Pans (2-1/2”)
650lbs (295kg)
SIDES
BACK
0
6 [152]
GSX-10HE
2
1-10 Pans (2-1/2”)
700lbs (318kg)
GSX-16HE
2
1-16 Pans (2-1/2”)
900lbs (408kg)
Total dissolved solids
Less than 60 PPM
Chlorine ......................... Less than 1.5 PPM
Total alkalinity
Less than 20 PPM
pH Factor ....................... 6.8 - 7.3
Silica ..................................... Less than 13 PPM
GSX-7HE & GSX-16HE
GSX-10HE