INSTALLATION & OPERATION MANUAL 10070 REV 0 (04/21)
PAGE
4
OF 32
G
as
F
ired
S
team
T
ilting
K
ettles
S
ervice
C
onnections
S
ERVICE
C
ONNECTIONS
GAS CHARACTERISTICS
DIMENSIONS
* For use on non-combustible floors only.
SERVICE CONNECTIONS
– GAS CONNECTION: Supply Gas through 3/4” pipe. A gas shut off valve must be installed in supply piping convenient and adjacent to appliance.
– ELECTRICAL CONNECTION : Unless otherwise specified, field wire electrical connection to be 120 volts, 60 Hz, 1 phase with grounding wire. Unit
furnished with 6’ cord and 3 prong plug. Total maximum amps 4.0.
– COLD WATER: 3/8” (10 mm) tubing to faucet (optional)
– HOT WATER: 3/8” (10 mm) tubing to faucet (optional)
Model
Capacity
Units
A
B
C
D
E
F
G
H
J
K
L
M
N
GLT-20
20 gallons
(76 liters)
in
(mm)
20”
(508)
48.13”
(1222)
40.63”
(1032)
19”
(483)
40.13”
(1019)
76.5”
(1943)
16.5”
(419)
24”
(610)
11”
(279)
22”
(559)
40.5”
(1029)
18.38”
(467)
25.5”
(648)
GLT-30
30 gallons
(114 liters)
in
(mm)
26”
(660)
55.25”
(1403)
43.63”
(1108)
16.5”
(419)
39”
(991)
73.75”
(1873)
15.5”
(394)
22.25”
(565)
7.5”
(191)
21”
(538)
38.13”
(968)
17.88”
(454)
28.5”
(724)
GLT-40
40 gallons
(152 liters)
in
(mm)
26”
(660)
55.25”
(1403)
43.63”
(1108)
16.5”
(419)
43.25”
(1099)
76”
(1930)
15.5
(394)
22.25”
(565)
7.5”
(191)
23”
(584)
42.5”
(1080)
22.13”
(562)
28.5”
(724)
GLT-60
60 gallons
(227 liters)
in
(mm)
30”
(762)
59”
(1499)
45.63”
(1159)
17.88”
(454)
43.88”
(1115)
82”
(2083)
19.5”
(495)
22.25”
(565)
5.5”
(140)
23”
(584)
45.5”
(1156)
24.75”
(629)
30.5”
(775)
Model
Gas Supply
Shipping
Weight
Minimum Clearance
BTU/HR.
kW/HR.
Supply Pipe Pressure (W.C.)
GLT-20
80,000
23.4
Natural
6”-14”
(152-356 mm)
Propane
11”-14”
(279-356 mm)
700 lbs. [318 kg]
SIDES
BACK
0” [0 mm]
4” [102 mm]
GLT-30
100,000
29.3
900 lbs. [408 kg]
GLT-40
100,000
29.3
930 lbs. [422 kg]
GLT-60
120,000
35.2
1142 lbs. [51 kg]
As continued product improvement is a policy of Crown, specifications are subject to changge without notice.