![Crown GLT-20 Installation & Operation Manual Download Page 8](http://html1.mh-extra.com/html/crown/glt-20/glt-20_installation-and-operation-manual_2690241008.webp)
INSTALLATION & OPERATION MANUAL 10070 REV 0 (04/21)
PAGE
8
OF 32
G
as
F
ired
S
team
T
ilting
K
ettles
O
peration
NOTICE
Contact the factory, the factory representative or a local service company to perform maintenance and repairs
should the appliance malfunction.
O
PERATION
WARNING
In the event of main burner ignition failure, a 5 minute purge period must be observed prior
to re-establishing ignition source.
CAUTION
If you smell gas during the lighting procedure, immediately shut off the gas supply until the leak has been corrected.
WARNING
In the event you smell gas, shut down equipment at the main shut off valve and contact the
local gas company or gas supplier for service.
G
as
C
ontrol
I
nstructions
The units do not require “lighting” the pilot with a match.
A. Lighting
NOTICE
Unit is shipped with gas combination valve turned “on”.
1. Open manual gas shut off valve.
2. Set thermostat to OFF, and kettle in fully upright position, turn power switch ON.
3. Set thermostat to maximum, initiating a 30 second pre-purge. Red “COOKING” pilot will come on, and after 30
seconds, the green “IGNITION” pilot will come on, lighting the main burners.
If after 36 seconds the burner fails to ignite or the “ignition light goes out, the system goes into Safety Lockout. De-
energize the system by setting the thermostat to “OFF” for five minutes and try again.
4. Set the thermostat to desired temperature setting. When temperature setting has been reached, the “IGNITION” pilot
will go off, turning off the burner. The unit will then cycle on and off to maintain set temperature.
NOTICE
When the kettle is tilted a safety switch will automatically turn off gas supply.
The kettle will not operate once it has been tilted.