New password : Change the Settings password.
Factory reset : Returns user settings to factory settings.
Back: Returns to previous function list
3.3.5
Factory Setting Functions
Factory settings are programmed by the manufacturer and are provided only to
authorized personnel.
3.3.6
Audio Monitor
Selects one of three points for monitoring audio at the front panel monitor jack.
• RF Monitor : A built in demodulator board for on-air monitoring.
• Audio Input : A direct sample of the audio input XLR connectors
• Audio Proc. Out : A demodulated sample of the composite audio
3.3.7
Fault Log
The Fault Log displays a record of faults. Sub functions in the Fault Log are:
View : Displays a list of five faults starting with the most recent. Choose from the
visible list or scroll forward or back to find a specific fault. The record of
each fault includes:
• Event
• Date
• Time
• Value
Clear : Removes all faults from log. Before actual clearing, the unit asks for a
password. It then asks if you are sure. This prevents accidental erasure.
Back : Returns to previous function list
RMS Board : Select RMS option ON/OFF
RMS Menu : Select this menu to change the three different phone numbers stored
in the RMS unit. Phone numbers are edited directly by selecting the
appropriate number. Phone # 1 will be the first number the RMS will
call when there is a fault. Phone # 2 is the second in case # 1 doesn’t
answer. Phone # 3 is the last and then repeats to # 1.
Peak View [month/day] : Displays the highest/lowest value for the faults within any
given day and the time the fault occured. These values
are cleared at 00:00 hour each day. Faults listed for
peak view are :
RF Power HIGH
RF Power LOW
Temp
Curr
SWR