Installation
2—13
You can enable an automatic turn-off of the carrier in the event of program failure.
To enable this option, selecte a setting from Table 2-3, Fault Time-out Values. The
time between program failure and carrier turn-off is set by a jumper (JP701) on the
voltage regulator board. (See Illustration 2–11, Chassis Bottom View, for board
location).
Delay
Pins to Jumper
30 seconds
1-2 (pins closest to edge)
2 minutes
3-4
4 minutes
5-6
8 minutes
7-8
Table 2-3 Fault Time-out Values
Illustration 2–11 Chassis Bottom View
Voltage Regulator
Filter
Capacitor
C1001
Power Regulator
AC Power Transformer
Bridge
Rectifier
AC Power
Entry
RF Predriver/Amplifier