19
IX InDIrEct & tanKlESS WatEr HEatEr PIPInG
InDIrEct WatEr HEatEr PIPInG
All FSZ series boilers are equipped with tappings to permit the connection of a Crown Mega-Stor, or other indirect water heater.
In this type of system, hot boiler water is drawn from below the water line and passed through the heat exchanger in the indirect
water heater. This section describes boiler-side piping only. Refer to the indirect water heater instruction manual for domestic
water piping. The components in this system and their functions are as follows:
1) Circulator - Mount the circulator as shown in Figure 9.1. The circulator should be located as low and as close to the boiler
as practical. Do not install valves, or other devices having a significant pressure drop between the boiler and the circulator inlet.
All piping between the boiler and the circulator inlet should be 1”, regardless of the size of the piping required in the rest of the
system. See Figure 11.2 in Part XI for wiring information.
2) “Y” Strainer - Install a “Y” strainer to prevent sediment from accumulating inside the indirect water heater.
3) Check Valve - Prevents gravity circulation through the indirect water heater when the boiler is responding to a call for heat.
4) Boiler Limit Control - Use a SPST break-on-rise temperature limit control such as the Honeywell L4006A. Do not set the limit
above 180F as doing so may cause the boiler to steam when there is no call for heat. See Figure 11.2 for wiring information.
5) Valves and Unions - Install shut-off valves, drain valves, and unions in locations that will facilitate maintenance of the system.
Do not install any valves between the boiler and circulator inlet.
FIGurE 9.1: InDIrEct WatEr HEatEr BOIlEr-SIDE PIPInG
Summary of Contents for FSZ080
Page 2: ......
Page 14: ...12 FIGURE 6 4 ALLAIR FROM OUTDOORS USING HORIZONTAL DUCTS INTO BOILER ROOM...
Page 18: ...16 FIGURE 8 1 STEAM BOILER PIPING FOR GRAVITY RETURN...
Page 26: ...24 FIGURE 10 2 TWO PIPE GRAVITY FEED SYSTEM NOT RECOMMENDED FIGURE 10 3 TWO PIPE LIFT SYSTEM...
Page 29: ...27 FIGURE 11 0 WIRING CONNECTIONS DIAGRAM STEAM CG450 PROBE LWCO...
Page 30: ...28 FIGURE 11 1 CONNECTIONS WIRING DIAGRAM FOR BURNER SPECIFIC PRIMARY CONTROL...
Page 31: ...29 FIGURE 11 2 INDIRECT WATER HEATER FIELD WIRING...
Page 41: ...39 Notes...
Page 43: ...41...
Page 45: ...43...
Page 47: ...45...
Page 51: ...Notes...