background image

Vortex FP Compact Installation & Operation Manual

13

Issue 1, January 2013

purpose is excluded except as prohibited by statute. This guarantee shall not affect a
customer’s statutory rights.

Customer Support

Tel:

+44 (0)1235 557711

Fax:

+44 (0)1235 557722

UK Office

Crowcon Detection
Instruments Ltd
2 Blacklands Way
Abingdon Business Park
Abingdon
Oxfordshire OX14 1DY
Tel: +44 (0)1235 557700
Fax :+44 (0)1235 557749
Email: [email protected]
Website: www.crowcon.com

USA Office

Crowcon Detection
Instruments Ltd
1455 Jamike Ave.
Erlanger
KY 41018
Tel: +1 859 957 1039 or
1 800 527 6926
Fax: +1 859 957 1044
Email: [email protected]
Website: www.crowcon.us

European Office

Crowcon Detection
Instruments Ltd
Vlambloem 129
3068JG
Rotterdam
Netherlands
Tel: +31 10 421 1232
Fax: +31 10 421 0542
Email: [email protected]
Website: www.crowcon.com

Singapore Office

Crowcon Detection
Instruments Ltd
Block 194 Pandan Loop
~06-20 Pantech Industrial
Complex
Singapore 128383
Tel: +65 6745 2936
Fax: +65 6745 0467
Email: [email protected]
Website: www.crowcon.com

China Office

Beijing Ker’Kang Instrument
Limited Company (Crowcon)
Unit 316, Area 1, Tower B,
Chuangxin Building, 12 Hongda
North Road, Beijing
Economic & Technological
Development Area, Beijing, PRC
100176
+86 10 6787 0335
Email: [email protected]
Website: www.crowcon.cn

Crowcon reserves the right to change the design or specification of this product without notice.

Summary of Contents for Vortex FP Compact

Page 1: ...Vortex FP Compact Flameproof Gas Detection Control System Installation and Operation Manual Issue 1 January 2013...

Page 2: ...described in this instruction manual has mains voltages applied to it Ensure correct safety procedures are adopted before working on the equipment The equipment described in this manual is designed f...

Page 3: ...TENTS 1 INTRODUCTION 3 1 1 SAFETY INFORMATION 3 1 2 PRODUCT DESCRIPTION 3 2 INSTALLATION 4 3 OPERATION MAINTENANCE 6 3 1 APPLYING POWER 6 3 2 COMMISSIONING 7 3 3 ROUTINE MAINTENANCE 7 3 4 VORTEX FP CO...

Page 4: ...ated control system designed for monitoring up to twelve gas detectors Three input channels may alternatively be used for monitoring conventional smoke or heat detectors or flame detectors Vortex FP C...

Page 5: ...the recognised standards of the appropriate authority in the country concerned and meet the electrical requirements of the field devices Field cables must be connected to the system using ATEX certifi...

Page 6: ...s Once the brackets are attached close the door and restrain using one fixing bolt before attempting to mount the cabinet 2 Lift the system in to place and secure via the mounting bracket fixing point...

Page 7: ...cted to the fused terminal A wiring diagram is shown on the next page If the equipment is permanently connected to a mains supply then a dedicated circuit breaker must be included in the installation...

Page 8: ...tallations are fully commissioned as soon as possible after installation Commissioning should include a full check of cabling and equipment functions as well as output functions Gas detectors must be...

Page 9: ...functions Vortex FP Compact must be completely de energised before the lid is opened local procedures must be adhered to when servicing equipment installed in a hazardous area 3 4 VORTEX FP COMPACT D...

Page 10: ...art cycling through the channels after HOLD has been selected or to end Channel Test mode Other display indications and functions are described below Feature Description System Fault LED Yellow LED in...

Page 11: ...ctions are shown below Warning access requires the Vortex FP Compact enclosure to be opened site procedures must be strictly adhered to before attempting to open the enclosure or to operate a powered...

Page 12: ...ftware can be used to inhibit individual channels Note Even in the inhibit condition the alarm LEDs on the display module are triggered if alarms occur 4 TECHNICAL SPECIFICATION Size 450mm x 330mm x 2...

Page 13: ...ter packaging of the returned goods Units returned to Crowcon as faulty and are subsequently found to be fault free or requiring service may be subject to a handling and carriage charge Warranty Discl...

Page 14: ...salesusa crowcon com Website www crowcon us European Office Crowcon Detection Instruments Ltd Vlambloem 129 3068JG Rotterdam Netherlands Tel 31 10 421 1232 Fax 31 10 421 0542 Email eu crowcon com Web...

Reviews: