Program Sequence List
We recommend that the
FW2 MERLIN PRO
is programmed on the bench before
taking it to the intended site. The factory default password is
111
.
1. First set the clock (NOT setting the clock gives an incorrect time stamp in the
Event Log).
2. Program all required detectors and remotes that are needed for the installation it
is recommended that the detectors are marked according to their assigned group
and zone.
3. Locate the detectors and the
FW2 MERLIN PRO
close to the point you want to
install them and perform the Radio signal strength test.
4. Change the password and record it for your/your customer files.
LCD Display Symbol Table
Table 1: Meaning of the Symbols Displayed on the LCD Screen
Icon
Meaning
Description
Tamper Switch Tamper transmission from a detector.
Alarm
Alarm transmission from a detector or remote key.
Supervision
Missed supervision transmissions for more then 120
minutes.
Low Battery
Low Battery on a Detector.
! Menu
New Event
New events recorded in the Event Log.
Arm
While the Input STAT set to Low ,its indicate that the unit
ARM
Entering Numbers
You can use the ▲ and ▼ buttons to enter numbers into the unit.
Button
Description
▲
Enter number from 1-9
▼
Enter number from 1-9
Examples of Number Sequences
Button Sequence
Number
▲▼▲
111
▲▼▼▲▲▲
123
▲▲▲▲ ▼ ▲▲
412