Functions
NOTE
While the FW2 MERLIN PRO is in normal operation it must display the main screen
or reported events will be ignored.
Function
Description
Outputs
Outputs 1 to 8 and Tamper are dry contact
(Not relative to GND)
Outputs 1 to 7
are Normally closed.
Output 8
: Relay with three terminals for, NO, NC, and C
(C-Common, NC- Normally closed, NO- Normally open)
Tamper
is normally closed.
STAT Input
When this Input is
Low
it indicates that the
Control Pane
l is armed.
In this mode all the events are recorded in the Log buffer.
Alarm event
Displayed on the LCD screen and activates the assigned output to
Open
for 3 seconds.
In
Armed
mode the event is displayed until disarmed.
Tamper
Event
Activates the tamper and then assigns Output to Open until restored.
Recorded in the event log.
Supervision
missing
If a detector is programmed as Supervised and the FW2 MERLIN
PRO does NOT receive any transmission from it for more than 120
minutes it indicates
Supervision
missing by beeping every 1 minute
as a warning and will record it on the events log.
Detector
Low Battery
When a detector transmits that it has
Low Batter
y the FW2 MERLIN
PRO will record it in the events log and will beep every 1-minute.
NOTE
The warning beeps will not sound while viewing the event lo
g or by pressing the ◄
key. The warning beeps will start again after the next Disarm.