2.0 Installation
The 4116-T300 Ka-Band Translator consists of a
8” Wide X 6” High X 16” Deep Weather Resistant*
enclosure
. A switching, ±12, +24, +5 VDC power supply provides power for the internal assemblies. The
4116-T300 can be secured to a mounting plate using the 4 holes on the bottom of the front and rear panels.
(See Figure 2.5 for mounting dimensions.)
Figure 2 - 4116-T300 Ka-Band Translator Front Panel
2.0.1 Connection to AC Input Power
The 4116-T300 is furnished with a pre-assembled AC power input cable as described below.
4116-T3
4116-T310 Power Input Connector, FCI Clipper Series, CL1M1102 & Crimp Pins
Mating
Mating Connector Clipper Series, CL1F1101 Crimp Pins
and CL
and CL101021 Backshell
Pin Input Connector Pin Description
1
100-240 ±10% VAC, 47-63 Hz, 20 watts max.
2
Neutral
3
Ground
2.1 Message Protocol
The serial format for the RS232/RS422/RS485 port is 9600 baud, 8 data bits, no parity, and 1 stop bit. All
messages consist of ASCII printable characters so standard terminals and terminal emulator programs may be
used to control and monitor the unit. All messages begin with the open bracket character “
{
”
(ASCII 0x7B) and
end with the close bracket character “
}
” (ASCII 0x7D). Messages consisting of commands to set or change
operating parameters and modes of the unit begin with “C” (ascii 0x43) followed by a command specific
character. Messages consisting of queries to report operating parameters and modes begin with “S”
(ASCII 0x53) followed by a parameter specific character.