2.6 Physical Interface

All  4115 and 4116 units provide a RS232/RS422/RS485 interface port and a 10/100 Base-T Ethernet port.  

Both ports are available when the unit is installed and powered up.  Commands may be sent to either port at any 

time and they will be processed in the order that they are received.  The RS232/RS422/RS485 signals connect 

via an 18-pin, MS3112E14-18S, 18 connector as shown in Table 2.6.  The Ethernet signals connect via a 

standard RJ45 connector, Part # RJF6G.

Table 2.6:  Monitor and Control Connector 

Table 

Table 2.6.1 - Monitor and Control Connector Pinouts

Conne

Connector part number MS3112E14-18S

Mating

Mating Cable Connector part number MS3116F14-18P

Pin  Signal Description

A

 Chassis Ground

N

 Summary Alarm Normally Closed

P

 Summary Alarm Common

R

 Summary Alarm Normally Open

E

 RS422/RS485 Data Out-

F

 Signal Ground

C

 RS422/RS485 Data In-

D

 RS422/RS485 Data Out+, RS232 Data Out

B

 RS422/RS485 Data In+, RS232 Data In

NOTE:  Planning Ethernet Access
It is recommended that IP knowledgeable customer personnel be consulted as a resource in the

        installation and use of the Ethernet access features of the Cross Technologies product.

4116-T300 Manual_F  

               Page 18

  

                                 11/05/15

Summary of Contents for 4116-T300

Page 1: ...ed without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment model number equipmen...

Page 2: ...t defective materials and workmanship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s...

Page 3: ...Resistant enclosures are designed to be water resistant for installation in an outdoor enclosure antenna hut OR mounted outdoors on an antenna assembly at their specified temperature ranges They are d...

Page 4: ...nd 9 8 800 8 3 9 8 19 2 20 2 28 0 29 0 Band 8 10 300 9 3 10 3 17 7 18 7 28 0 29 0 Band 7 8 300 8 3 9 3 19 2 20 2 27 5 28 5 Band 6 9 200 8 3 10 2 18 3 19 3 27 5 28 5 Band 5 9 800 8 8 10 3 20 2 21 2 30...

Page 5: ...1 1 dB steps Gain at Fc 105 93 77 75 65 1M 100K 10K 1K 100 dBC Hz Phase Noise Frequency Hz Gain Band select and internal 10MHz frequency via Ethernet M C or Status Control connector Gain Band 10M Fre...

Page 6: ...Crimp Pins and CL and CL101021 Backshell Pin Input Connector Pin Description 1 100 240 10 VAC 47 63 Hz 20 watts max 2 Neutral 3 Ground 2 1 Message Protocol The serial format for the RS232 RS422 RS485...

Page 7: ...steps if Band 1 is selected Range 500 to 1000 in 5 MHz steps yyyyy Translation Frequency Offset xx Band Range 1 to 11 where aaCxx yyyy Set Frequency Offset x 11 to select band 11 in 30 0 to 31 0 GHz O...

Page 8: ...eference x 1 to mute the output x 0 to unmute the output xx 2 characters where aaCEx Set 10 MHz reference mode Range 2000 to 2000 xxxxx 5 characters where aaCOxxxxx Set Int 10 MHz reference offset Ran...

Page 9: ...ected in 27 5 to 28 5 GHz x 10 if band 10 is selected in 28 0 to 29 0 GHz x 9 if band 9 is selected in 29 0 to 30 0 GHz x 8 if band 8 is selected in 28 0 to 29 0 GHz x 7 if band 7 is selected in 28 0...

Page 10: ...if Band 8 is selected Range 1000 to 500 in 5 MHz steps if Band 7 is selected Range 0 to 1000 in 5 MHz steps if Band 6 is selected Range 1000 to 0 in 5 MHz steps if Band 5 is selected Range 1000 to 900...

Page 11: ...ry alarm x 1 if summary alarm aaSA Unit Status Returns aaSTxxx where y 0 if unit is using internal 10 MHz ref y 1 if unit is using external reference Returns aaSAxy where Range 2000 to 2000 xxxxx 5 ch...

Page 12: ...16 T300 s Ethernet port to the LAN using a normal RJ 45 cable Use any PC on the LAN to connect to the 4116 T300 2 4 2 Ethernet Configuration Each 4116 T300 must be configured with an appropriate IP ad...

Page 13: ...k and Gateway address with delimiter dots example 192 168 192 47 2 4 3 Webpage M C Enter the following address in a web browser to access the M C webpage http ip address of 41xx serial 0 setup htm whe...

Page 14: ...using Windows XP s Hyper Terminal utility Start the Hyper Terminal application and select New Connection from the File drop down menu The next screen is a Connect To dialog box Select TCP IP Winsock...

Page 15: ...r SNMP community read and write strings After setting your desired community strings you will be prompted to Enter IP addresses for SNMP traps You must enter at least one and up to four IP addresses o...

Page 16: ...Figure 2 F Device Server Configuration Menu 4116 T300 Manual_F Page 16 11 05 15...

Page 17: ...19 2 to 20 2 Band 9 18 7 to 19 7 Band 10 19 0 to 20 0 Band 11 20 0 to 21 0 10MHz OUTPUT SMA female 50 output level input level 1 dB 10MHz INPUT SMA female 50 Insert External 10MHz Reference here 2 to...

Page 18: ...itor and Control Connector Table Table 2 6 1 Monitor and Control Connector Pinouts Conne Connector part number MS3112E14 18S Mating Mating Cable Connector part number MS3116F14 18P Pin Signal Descript...

Page 19: ...T for external 10 MHz 2 to 8 dBm reference that is inserted at J2 via Ethernet or serial command see Section 2 0 and Table 2 6 1 8 Check that a 10 MHz signal is present at the 10 MHz REF OUTPUT at the...

Page 20: ...ES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 4116 T300 Manual_F...

Reviews: