M&C Queries (continued)
Returns {aaSMx} where:
{aaSM}
Mute Status
x = 0 if mute is off
x = 1 if mute is on
xxxxxxxx = unit model number
{aaSV}
Model and firmware revision
xxx = 3 characters
{aaST}
Internal Temperature
x = 0 if no summary alarm, x = 1 if summary alarm
{aaSA}
Unit Status
Returns {aaSTxxx} where:
y = 0 if unit is using internal 10 MHz ref,
y = 1 if unit is using external reference
Returns {aaSAxy} where:
Range: +2000 to -2000
xxxxx = 5 characters
Returns {aaSOxxxxx} where:
{aaSO}
Int. 10 MHz reference offset
yyyy = unit firmware rev.
returns {aaSVxxxxxxxxyyyy} where:
Range (-99 to +99) degrees Celsius
Description
Syntax
Queries
4116-T300 Manual_F
Page 11
11/05/15