Figure 2.5 Shows front panel input and output connections, top view and baseplate mounting dimensions.
•
•
•
•
•
•
•
•
L-BAND OUT
J9
10M IN
STATUS /
CONTROL
ETHERNET
POWER
ALARM
J3
J4
10M OUT
FUSE
J8
AC IN
J7
F1
RF INPUT
J1
.
.
.
.
.
•
•
•
•
J6
C
ROSS
T
ECHNOLOGIES INC.
..
....
.....
....
...
ALARM LED
Red LED indicates
Downconverter alarm.
L-BAND OUTPUT
Type N (female) 50
Ω
0.95 to 2.45 GHz
Output level range
-20 to 0 dBm
POWER IN
AC input
100-240 ±10% VAC 47-63 Hz.
Weatherized CL1F1101 Connector
(See Paragraph 2.0.1)
POWER LED
Green LED indicates
DC voltage is present from
AC power supply.
RF INPUT
2.92 SMA (female),50
Ω
28.5-30.0 GHz, IN
ETHERNET CONNECTOR
Weatherized Standard
RJ45 Ethernet Connector
Fuse
1A/250V - 1.25” X 25”
slow blow.
10MHz INPUT
SMA (female) 50
Ω
Insert External 10MHz
Reference here (+2 dBm +8 dBm).
10MHz OUTPUT
SMA (female) 50
Ω
7.50
15.875
12.00
15.5
1/4-20 Tapped Thru, 4 Places
STATUS/CONTROL
CONNECTOR
Weatherized
MS3112E14-18S
Connector
(See Table 2.6.1)
6.62
4.2
7.88
MODEL 4116 Downconverter
RF MON
J2
.
RF MON
2.92 SMA (female),50
Ω
(Option W74 MKA)
4116-285-2450 Manual, Rev. 0
Page 14