2.3 M&C Queries
Table 2.1 - Model 4116-285-2450 Block Downconverter M&C Queries
yyyy = unit firmware rev.
xxxxxxxx = unit model number
returns {aaSVxxxxxxxxyyyy} where:
{aaSV}
Model and firmware revision
Range (-99 to +99) degrees Celsius
xxx = 3 characters
Returns {aaSTxxx} where:
{aaST}
Internal Temperature
y = 0 if unit is using internal 10 MHz ref,
y = 1 if unit is using external reference
x = 0 if no summary alarm, x = 1 if summary alarm
Returns {aaSAxy} where:
{aaSA}
Unit Status
Range: -2000 to 2000
xxxxx = 5 characters
Returns {aaSOxxxxx} where:
{aaSO}
Int. 10 MHz reference offset
x = 1 if RS422 is selected
Example: {aaSG245} indicates the current
gain setting is 24.5 dB
Range: 00 to 31
x = 2 if RS485 is selected
xx = 2 characters
Returns {aaSAxx} where:
{aaSR}
RS485 address
x = 0 if RS232 is selected
Returns {aaS
I
x} where:
{aaS
I
}
Serial Interface
Range:
300 to 000
(
+30 to 0 dB
)
xxx = 3 characters
Returns {aaSGxxx} where:
{aaSG}
Gain
Description
Syntax
Queries
Table 2.1: Model 4116-285-2450 M&C Queries
4116-285-2450 Manual, Rev. 0
Page 8