B) Status Requests
TABLE 1.2 3116-7786-2150 C
Commands
3116-7786-2150
Commands
TABLE 1.2 3116-7786-2150 Commands
Command
Syntax *
Description
Set Frequency
{aaCFxxxx}
where:
• aa = unit address, range = 00 to 31,
only used if interface is RS485, otherwise omit.
• F = command code
• xxxx=frequency in MHz, range = 7900-8500,
xxxxxxx = frequency in kHz if option - X, X1
(7900 to 8500 MHz, 1 MHz steps)
• example: {CF8250}
Will set the unit's frequency to 8250 MHz
The unit will reply with the '>' character if the
command is successfully processed.
Set Gain
{aaCGxxx}
where:
• xxx = Converter gain in 0.5 dB steps
Range: 050 to 350 where 300 = 30.0 dB
Example: {CG255} sets the converter's gain to +25.5 dB
Set Internal 10 MHz Reference Offset
{aaCOxxxxx} where:
• xxxxxx = Internal 10 MHz reference frequency offset.
Range: -2000 to +2000
Set 10 MHz Reference Mode
{aaCEx}
where:
• x = 0 if the converter's 10 MHz reference mode is set to Internal
• x = 1 if the converter's 10 MHz reference mode is set to External
• x = 2 if the converter's 10 MHz reference mode is set to Auto
Set Mute
{aaCMx}
where:
• x = 0 if the converter's RF output is NOT muted (RF output is ON)
• x = 1 if the converter's RF output is muted (RF output is OFF)
Set Output Path
{aaCDx}
Returns {aaSDx}where:
(option W116)
• x = 0 if selected output path is A.
3116-7786-2150 Manual, Rev. 0
Page 8
11/24/20