2.5.6 Input Level and Attenuation Changes
To change the Input Level, push the Menu/Execute switch until you get to:
INLVL = -20
R
When the display indicates the value desired you can push the Menu/Execute switch to the next item,
OR you can scroll to “R”, push the Menu/Execute switch to get to:
SAVE SETTINGS?
Y N
Selecting Y will save the new settings. Selecting N will revert to the previous settings.
Figure 2.4 gives the menu items and how to make changes
NOTE: CHANGES TAKE PLACE ON LEVEL AND GAIN IMMEDIATELY BUT DO NOT GET
SAVED UNTIL YOU GO TO THE SAVE MENU AND INDICATE YOU WANT TO SAVE THE
CHANGES.
If you do not wish to save the changes you have made, scroll to “R” and push the Menu/Execute switch and
select “NO” in the “SAVE SETTINGS?” window or do not press the Menu/Execute switch; simply do
nothing for approximately 30 seconds, and the system will return to the normal operating mode.
To change the translator attenuation, push the Menu/Execute switch until you get to the ATTN setting:
ATTN = 00
R
Press the Up/Down switch to change the attenuation in 1 or 10 dB steps.
ATTN = 10
R
By using the horizontal rocker switch the cursor can be moved left or right.
ATTN = 10
R
Pressing the Up/Down switch down will toggle the digit selected until you have the desired attenuation.
NOTE: THE ATTENUATION WILL CHANGE AS IT IS ADJUSTED, HOWEVER, THE VALUE
WILL NOT BE STORED UNTIL YOU INDICATE YES IN THE SAVE SETTINGS WINDOW.
When the display indicates the value desired you can push the Menu/Execute switch to the next item OR
you can scroll to “R”, push the Menu/Execute switch to get to:
SAVE SETTINGS?
Y N
Selecting Y will save the new settings. Selecting N will revert to the previous settings.
150 > 95
ATN=10 REF=INT
Figure 2.4 gives the menu items and how to make changes
2083-914A Manual
Page 15