2.5.5 140 MHz End Center Frequency Changes
The 140 MHz end (whether the Input or Output) can have the center frequency adjusted from 110 to 170 MHz.
Note that when the 140 MHz end is the Input, you must be sure that the input bandwidth can properly
pass through the 36 MHz bandwidth filter used in the translation. When the 140 MHz side is the Output it
will cause the 36 MHz bandwidth signal from the 95 MHz input to be centered at the output center frequency
that is selected.
At any time during the modification process, if you have made a mistake and do not wish to save the changes
you have made, do not press the MENU/EXECUTE switch; simply do nothing for approximately 30 seconds,
and the system will return to the normal operating mode or scroll to “R” and push the MENU/EXECUTE
switch and select “NO” in the “SAVE SETTINGS?” window. To change the Frequency Translation:
140 > 95 TRANSLATION MODE 140 MHZ END CENTER FREQUENCY CHANGES :
To change the 140 MHz end frequency, push the Menu/Execute switch until you get to:
IF IN = 140 MHz
R
Press the Up/Down switch to change the frequency in 1 or 10 MHz steps.
IF IN = 150 MHz
R
By using the horizontal rocker switch the cursor can be moved left or right.
IF IN = 150 MHz
R
Pressing the Up/Down switch down will toggle the digit selected until you have the desired frequency.
NOTE: CHANGES DO NOT TAKE PLACE ON FREQUENCY UNTIL YOU GO TO THE SAVE
MENU AND INDICATE YOU WANT TO SAVE THE CHANGES. THE CARRIER IS MUTED
WHEN FREQUENCY IS CHANGED.
When the display indicates the value desired you can push the Menu/Execute switch to the next item OR
you can scroll to “R”, push the Menu/Execute switch to get to:
SAVE SETTINGS?
Y N
Selecting Y will save the new settings. Selecting N will revert to the previous settings.
Pushing the Menu/Execute switch then takes you to:
150 > 95
ATN=00 REF=INT
2083-914A Manual
Page 13