![Cromtech Brumby CTG3000i Owner'S Manual Download Page 32](http://html.mh-extra.com/html/cromtech-brumby/ctg3000i/ctg3000i_owners-manual_2687163032.webp)
MAINTENANCE SCHEDULE
It is an owners requirement to periodically inspect, adjust,
lubricate and maintain their generator to keep it in good
working condition.
!
NOTE: Use only genuine parts for replacement.
!
WARNING: Consult your local service agent for all
major maintenance work.
!
WARNING: Stop the engine before starting
maintenance work.
Item
Maintenance
Procedure
Regular Service period
①
. Perform at every indicated month or
operating hour interval, whichever occurs first.
Before
Each Use
After first
4 to 6 hrs
Every
3 months
or 50hr
Every
6 months
or 100hr
Once
per year
or 300hr
Engine
Oil
Check
○
Change
○
○
Air
Cleaner
Check
○
○ Replace if dirty
Clean
○ ②
Spark
Plug
Clean/Adjust
○
Spark
Arrester
Check
○
Replace
Fuel Filter
Check
○
Replace
○ ②
Valve
Clearance
Check/Adjust
○ ③
Fuel
Tank &
Strainer
Clean
○ ②
Fuel Line
Check
Every 2 years (replace as necessary) ③
NOTES:
① Log hours of operation to determine proper maintenance.
② Service more frequently when used in dusty areas.
③ These items should be serviced by an authorized dealer unless the owner has
the proper tools and is mechanically proficient. See the Service Manual.
Service Period for Oil Changes
Normal Operating Temperature
100 hours (Normal)
25°C (77°F)
95 hours
30°C (86°F)
85 hours
35°C (95°F)
70 hours
40°C (104°F)
Pg. 32