SOLO1DEE
Page 11 / 32
Connection
The connection of the inverter should be done with utmost care. First connect the consumer devices so as to prevent any
further contact once the 230V tension is present. The technical data and connection’s description, is either under one
side of the inverter or onto the cable connection side. Installation is to be made only with authorised persons.
Connecting the consumer devices
The SOLO inverter is supplied with a 230V cable for the consumer devices. This connection must be done observing
the colours:
Yellow-green: earth
Brown: phase
Blue: neutral
Once the consumer devices are connected, make sure that they are turned off before connecting the battery
Note
An inverter constitutes an independent power supply from net and could be considered in the same way as a generator
set. The phase and the neutral are not differentiate. The tension in between the phase and the neutral is 230V. An
appropriate divisor establishes a 115V voltage in between neutral and earth, and the phase and earth. According to the
local prescriptions or particular requirement, (example: use of a ground fault detector) a true neutral may be established
by connecting the neutral and the earth wire together. The so connected point, may be connected with an existing earth:
earth of building; the chassis of vehicle or the hull of ship.
Equivalent schema
Connecting the battery
Once the consumer devices are connected, make sure that the installations instructions of the 230V has been followed
with utmost care
before connecting the battery
.
The cable of the battery is supplied with the inverter and already connected in it.
A fuse must be installed on the battery.
Connect the battery observing carefully the polarity. The SOLO inverter,
except 2000W/12V,
is protected against
inversion by a fuse, but if the polarity should be inverted, the inverter must be sent to the manufacturer for control.
Connect the battery using the following colours:
BLACK cable: negative pole (-)
RED cable: positive pole (+)
For SOLO 200W/300W, dominant colour is applicable
(not existing in SOLO 12V/200W, SOLO 24V/300W, SOLO 48V/300W)
Summary of Contents for SOLO 1000
Page 2: ...SOLO1DEE Page 2 32...
Page 28: ...SOLO1DEE Page 28 32...
Page 29: ...SOLO1DEE Page 29 32...
Page 30: ...SOLO1DEE Page 30 32...
Page 31: ...SOLO1DEE Page 31 32...