M5 16/32/48/60-M-A/E-O
Created on 4/14/2011 8:18:00 AM
6
BEGIN SERIAL NO. 09010131
L.
If the machine is supplied with the Ventless Hood, refer to the Giles instruction manual for
more details on the operation and components. The popcorn popper will not operate if the
Giles hood is not fully functional, as part of the UL / EPA testing requires.
M.
If the machine is supplied with the ansul option, in the case of a fire, fire suppression liquid
will be discharged into the kettle and cabinet to put out the fire. Power to the circuits will
be cut except to the Giles hood.
Ansul must be called to initiate the system at start up
.
VII. CONTROL SWITCHES (not all switches are provided on all machines)
*KETTLE HEAT
-Turns the kettle heat On/Off (see exhaust for ventless option)
AGITATOR
-Turns the stirrer blade motor On/Off.
*EXHAUST
-Turns exhaust blower On/Off.
*
Ventless Hood option
-The exhaust switch must be turned on for the kettle to heat.
CORNDITIONER
-Turns the cornditioner blower and heat On/Off.
LIGHTS
-Turns interior lights On/Off.
OIL
-Provides power to the oil pump.
DELIVERY
-Initiates the pump cycle.
FUSE/CIRCUIT BREAKER
-Provides protection to all circuits, except the kettle.
ROTARY SWITCH
-Turns power On/Off to all circuits.
ONE POP SWITCH
-Turns the kettle heat on and initiates the pump cycle.
SALT/SUGAR SWITCH
-Sets the pump and kettle temperature to proper settings.
DIGITAL CONTROLLER
-Displays and controls kettle temperature.
VIII. OPERATING INSTRUCTIONS
Do not attempt to operate your Cretors popcorn machine until you have read and
understood this manual. Failure to do so may result in serious injury or death.
Do not attempt to operate your Cretors popcorn machine unless the installation
instructions have been strictly adhered to. Failure to do so may result in serious injury
or death.
Operate your popcorn machine only if it is in sanitary condition (See
SANITATION