Cretors EG20 Service Manual Download Page 7

  

EG20/32/48/60-M-A/E-S 

Last printed 9/10/2007 1:56:00 PM 

BEGIN SERIAL NO: 00035540 

  

 

D.

 

OEM Option Pedestals 

 

  

1.

 

OEM OPTION machines are designed to supply power to the components 
normally associated with the popcorn machine.  The primary features are a 
power cord with plug and a flexible armored cable to be connected to the 
user’s cornditioner assembly (15 amps).  In addition, a terminal strip inside 
the pedestal provides a connection point to a switch (15 amps) that will 
control a user’s exhaust fan.  Mounting studs for fluorescent ballast and a 
connection point for a light circuit are also supplied.  

  

2.

 

EXHAUST FAN CONTROL machines may be equipped with a time delay 
fan control.  This control provides a timer controlled switch that will turn 
on a customers exhaust fan when the kettle heat is turned on.  When the 
heat is turned off the fan will continue to run for the time set on the timer in 
the pedestal.  This circuit only provides a switch, it does not supply any 
power.  

  

All electrical connections outside the pedestal must be done in accordance 
with appropriate electrical codes and requirements.  

  

E.

 

Pump Installation & Timer Adjustment for Salt/Sugar Machines  

 

  

Refer to the Service Manual included with the pump to be installed in the 
machine.  When the Giant is equipped with the salt/sugar option, also see below 
for additional information.  
  

1.

 

For the Salt/Sugar machine the pump timers are located in the machine 
not in the pump.  One timer is marked “Salt”, the other “Sugar”.  The 
timers are located in the pedestal.  

  

2.

 

To adjust the pump time, use the following procedure:  

  

a.

 

There are two adjustments on the timer.  The small adjustment knob 
sets the maximum time the timer can run.  Cretors will normally set 
this adjustment for 10s.  

  

10s = 0-10 seconds  
1m = 0-1 minute  
10m = 0-10 minutes  
  

b.

 

The larger adjustment knob sets the actual run time (percentage of 
time allowed by the small adjustment knob).  Example:  If the 
maximum setting is set for 10s and the large knob is set at .9, the timer 
will run for 9 seconds.  Adjust to taste for both timers.  

  

 
 

Summary of Contents for EG20

Page 1: ...and Three Phase 60 Hz 120 240 Volt Single and Three Phase 60 Hz 230 Volt Single Phase 50 Hz 400 Volt Three Phase 50 Hz 100 200 Volt Single Phase 50 60 Hz Included in this manual One Pop Option Salt S...

Page 2: ...ons 6 A Location B Power Supply C Connecting Machine to Power Supply D OEM Option Pedestals 7 E Pump Installation Timer Adjustment for Salt Sugar Machines VII Service Instructions 8 A Parts B Kettle T...

Page 3: ...f 29 CFR 1926 20 b 4 a 2 It is understood that safety rules within individual companies vary If a conflict exists between the safety procedures contained in this manual and the rules of a using compan...

Page 4: ...EG20 32 48 60 M A E S Last printed 9 10 2007 1 56 00 PM 4 BEGIN SERIAL NO 00035540 CONFIGURATOR PAGE...

Page 5: ...P Capacity 32 oz All Steel Kettle 640 one ounce servings per hour Wattage 4500 watts Dimensions 10 5 8 D x 10 1 2 W x 31 3 4 H 27 cm D x 26 cm W x 81 cm H Net Weight 74 lbs 33 6 kg MODEL EG48 GIANT 48...

Page 6: ...the correct power source Failure to do so may result in personal injury or death and may damage your popper 2 C Cretors and Company recommends dedicated circuits for the Giant model popcorn machine Th...

Page 7: ...ircuit only provides a switch it does not supply any power All electrical connections outside the pedestal must be done in accordance with appropriate electrical codes and requirements E Pump Installa...

Page 8: ...operation The kettle indicator light indicates the operation of the temperature control If equipped the indicator light is located on the switch plate The indicator light will turn off 10 20 seconds b...

Page 9: ...t out with the new kettle assemblies for reference 2 DIGITAL TEMPERATURE CONTROL ADJUSTMENT CAUTION If the corn has dried out it may not finish popping at normal temperatures and the light may appear...

Page 10: ...10 to 20 seconds prior to dumping the kettle 4 SALT TIMER ADJUSTMENT For machines supplied with Salt Sugar Option only When the Salt Sugar switch is in the sugar mode the thermostat alone controls th...

Page 11: ...the number side opposite of the open side Switch 6 5 seconds 7 10 seconds 8 20 seconds 9 40 seconds Example If you turn 7 and 9 on the time delay will be 50 seconds C Kettle Removal To remove the ket...

Page 12: ...n front terminal left to right Black on back terminal 5 Replace the terminal box cover 6 Turn on the agitator motor and dump the kettle If the drive shaft does not engage and dis engages freely readju...

Page 13: ...f no load is applied Once the kettle heat and auxiliaries are turned on the voltage may drop 5 to 10 volts Use an ammeter to diagnose Indicator light stays on Digital Control never reaches temp One of...

Page 14: ...off one of the element terminals due to a loose connection In either case the kettle must be removed and the problem identified 1 Remove kettle See section Kettle Removal for instructions 2 Check for...

Page 15: ...irs on the power supply circuit unless you are qualified to do so The electrical shock associated with line voltages can cause serious injury or death The following procedures are performed with the p...

Page 16: ...2000 Watt 28 8 4250 Watt 13 6 total 48 oz 60 oz 208V elements 1010 D 1808 D 1447 D 1043 D 750 Watt 57 7 1250 Watt 34 7 1800 Watt 24 0 2000 Watt 21 6 5800 Watt 7 5 total 48 oz 60 oz 240V elements 1010...

Page 17: ...g for heat and providing power to the relay contactor If the coil reading is not 120 volts 230 volts on 230V and 400V 50Hz machines the problem is in the temperature control 4 If the coil reading is 1...

Page 18: ...on a regular basis the popping oil will build up and turn to carbon on the inside of the blade center When this happens the clearance between the blade center and the pan center is reduced from 1 8 3m...

Page 19: ...rs and Company at the address listed below Please provide model and serial number when requesting additional copies of this manual There will be a nominal charge for additional copies Cretors guarante...

Reviews: