Cretors EG20 Service Manual Download Page 6

  

EG20/32/48/60-M-A/E-S 

Last printed 9/10/2007 1:56:00 PM 

BEGIN SERIAL NO: 00035540 

  

VI.

 

INSTALLATION INSTRUCTIONS 

 

 

 

A.

 

Location

  

  

Choose a location for your Cretors popcorn machine that maximizes the ease of 
operation and maintenance procedures.  Giant pedestal popcorn machines are 
designed to be installed on the customers counter or custom design cabinet.  
OEM option machines are supplied with components that permit them to be 
installed into a user’s cabinet and control the cornditioner, lights and exhaust in 
the cabinet (see details below).  Be sure to check your local building and fire 
codes for location restrictions.  

  

B.

 

Power Supply 

 

  

1.

 

Check the nameplate to determine the required power supply.  

  

  

Connect your popcorn popper only to the correct power source.  Failure 
to do so may result in personal injury or death and may damage your 
popper.

  

  

2.

 

C. Cretors and Company recommends dedicated circuits for the Giant 
model popcorn machine.  The Giant model poppers require a dedicated 
circuit to avoid a voltage drop in the supply wiring.  Check your local 
electrical codes regarding fuse or circuit breaker requirements.  

  

  

Make certain your popcorn machine is properly grounded.  Failure to do 
so may result in damage to your equipment or present a shock hazard.

  

 

C.

 

Connecting Machine to Power Supply 

 

  

1.

 

Make certain that power supply circuit breakers are in the off position.  

  

2.

 

Locate the pedestal and bolt it down securely using the four bolt holes 
provided in the base of the pedestal.  

  

3.

 

Power should be connected through one of the four large holes in the base 
of the pedestal.  

  

4.

 

The electrical connection is made to the terminal strip, located to the right 
of the main switch.  

  

Summary of Contents for EG20

Page 1: ...and Three Phase 60 Hz 120 240 Volt Single and Three Phase 60 Hz 230 Volt Single Phase 50 Hz 400 Volt Three Phase 50 Hz 100 200 Volt Single Phase 50 60 Hz Included in this manual One Pop Option Salt S...

Page 2: ...ons 6 A Location B Power Supply C Connecting Machine to Power Supply D OEM Option Pedestals 7 E Pump Installation Timer Adjustment for Salt Sugar Machines VII Service Instructions 8 A Parts B Kettle T...

Page 3: ...f 29 CFR 1926 20 b 4 a 2 It is understood that safety rules within individual companies vary If a conflict exists between the safety procedures contained in this manual and the rules of a using compan...

Page 4: ...EG20 32 48 60 M A E S Last printed 9 10 2007 1 56 00 PM 4 BEGIN SERIAL NO 00035540 CONFIGURATOR PAGE...

Page 5: ...P Capacity 32 oz All Steel Kettle 640 one ounce servings per hour Wattage 4500 watts Dimensions 10 5 8 D x 10 1 2 W x 31 3 4 H 27 cm D x 26 cm W x 81 cm H Net Weight 74 lbs 33 6 kg MODEL EG48 GIANT 48...

Page 6: ...the correct power source Failure to do so may result in personal injury or death and may damage your popper 2 C Cretors and Company recommends dedicated circuits for the Giant model popcorn machine Th...

Page 7: ...ircuit only provides a switch it does not supply any power All electrical connections outside the pedestal must be done in accordance with appropriate electrical codes and requirements E Pump Installa...

Page 8: ...operation The kettle indicator light indicates the operation of the temperature control If equipped the indicator light is located on the switch plate The indicator light will turn off 10 20 seconds b...

Page 9: ...t out with the new kettle assemblies for reference 2 DIGITAL TEMPERATURE CONTROL ADJUSTMENT CAUTION If the corn has dried out it may not finish popping at normal temperatures and the light may appear...

Page 10: ...10 to 20 seconds prior to dumping the kettle 4 SALT TIMER ADJUSTMENT For machines supplied with Salt Sugar Option only When the Salt Sugar switch is in the sugar mode the thermostat alone controls th...

Page 11: ...the number side opposite of the open side Switch 6 5 seconds 7 10 seconds 8 20 seconds 9 40 seconds Example If you turn 7 and 9 on the time delay will be 50 seconds C Kettle Removal To remove the ket...

Page 12: ...n front terminal left to right Black on back terminal 5 Replace the terminal box cover 6 Turn on the agitator motor and dump the kettle If the drive shaft does not engage and dis engages freely readju...

Page 13: ...f no load is applied Once the kettle heat and auxiliaries are turned on the voltage may drop 5 to 10 volts Use an ammeter to diagnose Indicator light stays on Digital Control never reaches temp One of...

Page 14: ...off one of the element terminals due to a loose connection In either case the kettle must be removed and the problem identified 1 Remove kettle See section Kettle Removal for instructions 2 Check for...

Page 15: ...irs on the power supply circuit unless you are qualified to do so The electrical shock associated with line voltages can cause serious injury or death The following procedures are performed with the p...

Page 16: ...2000 Watt 28 8 4250 Watt 13 6 total 48 oz 60 oz 208V elements 1010 D 1808 D 1447 D 1043 D 750 Watt 57 7 1250 Watt 34 7 1800 Watt 24 0 2000 Watt 21 6 5800 Watt 7 5 total 48 oz 60 oz 240V elements 1010...

Page 17: ...g for heat and providing power to the relay contactor If the coil reading is not 120 volts 230 volts on 230V and 400V 50Hz machines the problem is in the temperature control 4 If the coil reading is 1...

Page 18: ...on a regular basis the popping oil will build up and turn to carbon on the inside of the blade center When this happens the clearance between the blade center and the pan center is reduced from 1 8 3m...

Page 19: ...rs and Company at the address listed below Please provide model and serial number when requesting additional copies of this manual There will be a nominal charge for additional copies Cretors guarante...