Program Checks
Actions that can be performed on the HD-MD8X1/2 vary depending on whether it is
connected via Cresnet or Ethernet.
Cresnet Connections
For Cresnet connections, using Crestron Toolbox, display the network device tree
(
Tools | Network Device Tree View
) to show all network devices connected to the
control system. Right-click on the HD-MD8X1/2 to display actions that can be
performed on the HD-MD8X1/2.
Ethernet Connections
For Ethernet connections, using Crestron Toolbox, display the “System Info”
window (
Tools | System Info
) and select the
Functions
menu to display actions that
can be performed on the HD-MD8X1/2.
Be sure to use Crestron Toolbox to create the HD-MD8X1/2’s IP table.
1.
Select
Functions
|
IP Table Setup
.
2.
Add, modify, or delete entries in the IP table. The HD-MD8X1/2 can have
only one IP table entry.
3.
A defined IP table can be saved to a file or sent to the device.
Edit the control system’s IP table to include an entry for the HD-MD8X1/2. The
entry should list the HD-MD8X1/2’s IP ID (specified on the HD-MD8X1/2’s IP
table) and the internal gateway IP address 127.0.0.1.