background image

Crestron 

BB-6X-DSW

 

 

Pre-Construction Wall Mount Back Box

 

The dimensions of the BB-6X-DSW are shown in the following illustration. 

BB-6X-DSW Overall Dimensions (Front View) 

12.00 in

(30.46 cm)

6.35 in

(16.13 cm)

8.88 in

(22.54 cm)

9.06 in

(23.01 cm)

8.00 in

(20.32 cm)

5 in

(127 mm)

9 in

(227 mm)

7 3/4 in

(197 mm)

6 3/4 in

(171 mm)

6 in

(152 mm)

5 7/8 in

(148 mm)

6 3/16 in

(155 mm)

6 1/4 in

158 mm)

 

Installation Guide – DOC. 6728A 

Pre-Construction Wall Mount Back Box: BB-6X-DSW  

  3 

Summary of Contents for Pre-Construction Wall Mount Back Box BB-6X-DSW

Page 1: ...Crestron BB 6X DSW Pre ConstructionWallMountBackBox forTPS 6X DSW Installation Guide ...

Page 2: ...n by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respective owners 2008 Crestron Electronics Inc ...

Page 3: ...iption 1 Setup 5 Assembly 5 Mounting 5 Installation 7 Other Mounting Option Accessories 8 Resources 9 Industry Compliance 9 Reference Documents 9 Further Inquiries 9 Future Updates 9 Return and Warranty Policies 10 Merchandise Returns Repair Service 10 CRESTRON Limited Warranty 10 Installation Guide DOC 6728A Contents i ...

Page 4: ......

Page 5: ...ety of fittings and a blank cover plate is included NOTE If mounting into a material other than drywall for example wood lectern concrete or rock use the cutout template available in the post construction kit MMK 6X DSW or TMK 6X DSW NOTE For concrete and rock mounting material allow for proper ventilation before mounting the TPS 6X DSW The table below lists all parts included with the BB 6X DSW S...

Page 6: ...ack Box Crestron BB 6X DSW The mounted view of the BB 6X DSW is shown in the following illustration BB 6X DSW Mounted View Optional Cover Plate Attached 2 Pre Construction Wall Mount Back Box BB 6X DSW Installation Guide DOC 6728A ...

Page 7: ...tion BB 6X DSW Overall Dimensions Front View 12 00 in 30 46 cm 6 35 in 16 13 cm 8 88 in 22 54 cm 9 06 in 23 01 cm 8 00 in 20 32 cm 5 in 127 mm 9 in 227 mm 7 3 4 in 197 mm 6 3 4 in 171 mm 6 in 152 mm 5 7 8 in 148 mm 6 3 16 in 155 mm 6 1 4 in 158 mm Installation Guide DOC 6728A Pre Construction Wall Mount Back Box BB 6X DSW 3 ...

Page 8: ... 8 25 cm 10 50 in 26 65 cm 3 31 in 8 41 cm 1 50 in 3 81 cm NOTE Knockout holes are intended for Class 2 wiring only and are and diameter BB 6X DSW Overall Dimensions Cover Plate 0 03 in 0 08 cm 7 00 in 17 78 cm 9 85 in 25 02 cm 4 Pre Construction Wall Mount Back Box BB 6X DSW Installation Guide DOC 6728A ...

Page 9: ...OTE If your installation is not on wooden studs be sure to consider the needs of your particular situation For example screw type may vary for steel studs etc To mount the back box complete the following procedure refer to illustration on the following page 1 Position the back box against the stud so the extended edge of the attached mounting plate covers the front edge of the stud Be sure the sid...

Page 10: ...the Back Box ENSURE THESE SURFACES ARE FLUSH BACK BOX MOUNTING ENCLOSURE ASSEMBLY 4507462 NOTE BE SURE THE ASSEMBLY IS LEVEL WHEN MOUNTED SCREW 1 08 8B x SELF TAPPING FOR GROUNDING 2007277 6 Pre Construction Wall Mount Back Box BB 6X DSW Installation Guide DOC 6728A ...

Page 11: ...holes on the front of the back box must be exposed to accept the TPS 6X DSW mounting screws The holes are found beneath the drywall just outside of the four corners of the opening made by cutting out the drywall Refer to the NOTE in Mounted View with Cover Plate above Installation Complete the installation by either installing the TPS 6X DSW leaving the hole open if permitted by local building cod...

Page 12: ...ed to patch the area Crestron provides the following accessories MMK 6X DSW Doc 6779 for larger repairs and to fill in larger irregularities around the opening requires plastering TMK 6X DSW Doc 6780 for smaller repairs and to provide a smooth edge at the opening This option provides a finished appearance and is preferred when wallpaper is hung The manuals for the MMK 6X DSW and TMK 6X DSW are ava...

Page 13: ...es If you cannot locate specific information or have questions after reviewing this guide please take advantage of Crestron s award winning customer service team by calling Crestron at 1 888 CRESTRON 1 888 273 7876 You can also log onto the online help section of the Crestron website www crestron com onlinehelp to ask questions about Crestron products First time users will need to establish a user...

Page 14: ...r 90 days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for whic...

Page 15: ...Crestron BB 6X DSW Pre Construction Wall Mount Back Box This page is intentionally left blank Installation Guide DOC 6728A Pre Construction Wall Mount Back Box BB 6X DSW 11 ...

Page 16: ...Crestron Electronics Inc Installation Guide DOC 6728A 15 Volvo Drive Rockleigh NJ 07647 2021897 Tel 888 CRESTRON 12 08 Fax 201 767 7576 Specifications subject to www crestron com change without notice ...

Reviews: