System Digital Reserved Join Numbers for TPS-3000L Touchpanels (continued) 

JOIN # 

FUNCTION 

VALUE 

IN/OUT 

17232 

System Standby 

Time Out 

Decrease 

INPUT 

17242 System 

Run  Setup  INPUT 

17295 

System LCD 

Brightness 

Auto Off 

INPUT/OUTPUT 

17296 

System LCD 

Brightness 

Auto Threshold 

Increase 

INPUT 

17297 

System LCD 

Brightness 

Auto Threshold 

Decrease 

INPUT 

 

System Analog Reserved Join Numbers for the TPS-3000L Touchpanels 

JOIN # 

FUNCTION 

VALUE 

IN/OUT 

17200 

System Cresnet ID 

ID 

INPUT/OUTPUT 

17201 

System LCD 

Brightness 

INPUT/OUTPUT 

17203 

System Standby 

Time Out 

INPUT/OUTPUT 

17218 

System LCD 

Brightness 

Auto Threshold 

OUTPUT 

 

17219 

System Light 

Sensor 

Light Sensor 

Value 

OUTPUT 

 

Audio Digital Reserved Join Numbers for TPS-3000L Touchpanels 

JOIN # 

FUNCTION 

VALUE 

IN/OUT 

17300 Audio 

On 

INPUT/OUTPUT 

17301 

Audio 

Off 

INPUT/OUTPUT 

17302 Audio 

Beep 

On 

INPUT/OUTPUT 

17303 

Audio Beep 

Off 

INPUT/OUTPUT 

17304 

Audio Beep Volume 

Increase 

INPUT 

17305 

Audio Beep Volume 

Decrease 

INPUT 

17306 Audio 

Line 

On 

INPUT/OUTPUT 

17307 

Audio Line 

Off 

INPUT/OUTPUT 

17308 

Audio Line Volume 

Increase 

INPUT 

17309 

Audio Line Volume 

Decrease 

INPUT 

17312 Audio 

Wave 

On INPUT/OUTPUT 

17313 

Audio Wave 

Off 

INPUT/OUTPUT 

17314 

Audio Wave 

Volume 

Increase INPUT 

17315 

Audio Wave 

Volume 

Decrease 

INPUT 

17318 

Audio Mic AGC 

On 

INPUT/OUTPUT 

17319 

Audio Mic AGC 

Off 

INPUT/OUTPUT 

(continued on next page) 

34  

  6.4 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-3000L 

Operations Guide – DOC. 6077 

Summary of Contents for Isys TPS-3000L

Page 1: ...Crestron Isys TPS 3000L 6 4 Inch Lectern Wall Mounted Touchpanel Operations Guide ...

Page 2: ...n by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respective owners 2002 Crestron Electronics Inc ...

Page 3: ... Programming Software 23 Programming with the Crestron AppBuilder 24 Programming with SIMPL Windows 24 Programming with VisionTools Pro e 28 Quick Pushbuttons 32 Reserved Join Numbers 32 MultiByte International Characters 36 Uploading and Upgrading 36 Communication Settings 37 Uploading a SIMPL Windows Program 39 Uploading a VT Pro e Project 40 Firmware Upgrade 42 Problem Solving 44 Troubleshootin...

Page 4: ......

Page 5: ...uffix is omitted Featuring a 6 4 active matrix display that provides the finest quality video and graphics available on a screen of its size the TPS 3000L features the 65 536 color Isys engine which allows all graphics to be displayed with incredible brightness and depth A light sensor automatically brightens or dims the display with room light for easy viewing TPS 3000L Functional Summary 6 4 1 2...

Page 6: ... features five engraveable pushbuttons that are backlit for easy viewing These buttons can be programmed to access regularly used functions Each button also features LED feedback with adjustable brightness to indicate operation The purpose of the TPS 3000L touchpanel is to replace large complicated hard wired panels in either a Cresnet system or an RS 232 system with a series of simpler screens ea...

Page 7: ...ions 4 SIMPL Windows smw spz bin csz projectname smw source file projectname spz compiled file for 2 Series projectname bin compiled file for CNX generation projectname csz compiled file for CNX generation with SIMPL VT Pro e vtp vtz projectname vtp source file projectname vtz compiled file Firmware csf TPS 3000xxxxxx csf panel firmware Audio Balanced 20 kΩ unbalanced 10 kΩ line level stereo input...

Page 8: ...hite or almond CPU 63MIPs Coldfire processor running Isys generation firmware Cresnet Via 4 position mini phoenix connector RS 232 RJ11 connector for console telestrator etc Default settings 115200 8 bit parity none stop bit 1 Operating Temperature and Humidity 50º to 113º F 10º to 45º C 10 to 90 Relative Humidity non condensing Dimensions and Weight with faceplate Height 7 65 in 19 43 cm Width 9 ...

Page 9: ...photosensor and a microphone The electronic hardware is housed in a metal enclosure with a colored faceplate as shown after this paragraph All audio video RS 232 network and power connections are made at the rear of the unit This touchpanel is designed for placement in a wall or on a lectern podium When placing in a wall the touchpanel should be installed with the pushbuttons on the left side of t...

Page 10: ...n 21 84 cm 6 57 in 16 69 cm 0 32 in 0 81 cm 2 30 in 5 84 cm 8 45 in 21 46 cm 2 67 in 6 78 cm 7 65 in 19 43 cm 9 36 in 23 77 cm 2 81 in 7 29 cm 0 40 in 1 00 cm Physical View of the TPS 3000L Touchpanel Back 7 00 in 17 79 cm 8 05 in 20 45 cm 6 6 4 Inch Lectern Wall Mount Touchpanel Crestron Isys TPS 3000L Operations Guide DOC 6077 ...

Page 11: ...ating the wire gauge for a particular Cresnet run the length of the run and the power factor of each Cresnet unit to be connected must be taken into consideration If Cresnet units are to be daisy chained on the run the power factor of each network unit to be daisy chained must be added together to determine the power factor of the entire chain The length of the run in feet and the power factor of ...

Page 12: ...snet identity code NET ID These codes are recognized by a two digit hexadecimal number ranging from 03 to FE Refer to Interface Menu on page 13 for instructions on setting the unit s NET ID The NET ID of the unit must match the NET ID specified in the SIMPL Windows program Refer to Setting the Net ID in Device Settings on page 26 for information about changing the ID in a SIMPL Windows program Scr...

Page 13: ...shbuttons must be reoriented to match the position of the touchpanel Follow the instructions below to reorient the pushbuttons Pushbutton Layout and Join Number Assignment Lectern Mount 5 4 3 2 1 NOTE This Procedure should be done before installing the touchpanel Required Tools 1 Phillips tip screwdriver 1 Place the touchpanel on a flat surface 2 Remove the faceplate if installed and the pushbutto...

Page 14: ...le 5 Release the tension clip on the ZIF connector labeled J1 by gently sliding the clip approximately 1 16 toward the pushbutton circuit board edge and remove the ribbon cable from the connector Refer to the pictures after this step for a detailed view NOTE Do not pull the cable before releasing the tension clip Release the Tension Connector Connector Locked left Unlocked right 10 6 4 Inch Lecter...

Page 15: ...t the screen to inverted operation Refer to Screen Settings on page 15 for instructions 11 Rotate the touchpanel so the pushbuttons are located on the right side of the touchpanel If custom engraved button caps exist install them to match programming 12 With the faceplate buttons on the right place the supplied Crestron label on the faceplate over the molded Crestron logo which is now upside down ...

Page 16: ... with the Perform Calibration button or return to the previous screen with the Return button Choose an option by touching the correct button If you proceed to calibrate the touchpanel the screen displays the message Touch Upper Left centered on the panel with a cross hair in the corner Touch the cross hair in the corner of the screen to initiate calibration Another message Touch Upper Right appear...

Page 17: ...ENU shown to the left press the Audio button from the SETUP MENU The AUDIO MENU offers a series of buttons which opens additional screens and each is detailed in a table after this paragraph Two of the buttons on the AUDIO MENU perform a function directly The Restore Default Settings button returns all audio parameters to their default factory settings when the button is selected After audio param...

Page 18: ...m the SETUP MENU to display the video screen shown to the left The video source type can be specified by selecting Select Input The touchpanel can be configured to auto detect BNC and Twisted Pair TP connections S Video or Composite or can be set to a specific connection type BNC S Video BNC Composite TP S Video TP Composite Select the appropriate input mode The Show Controls button on the video s...

Page 19: ...brightness contrast saturation and hue 2 Each screen has its own Return button to revert to the SETUP MENU Screen Settings SCREEN SETTINGS Screen brightness orientation and pushbutton settings may need to be adjusted because of ambient light conditions or personal preference These screen attributes may be automatically set via programming or be altered manually by selects made from the SCREEN SETT...

Page 20: ...he UP and DOWN buttons to increase and decrease the THRESHOLD VALUE respectively If the CURRENT VALUE has exceeded the THRESHOLD VALUE the screen switches to high brightness When the CURRENT VALUE is less than the THRESHOLD VALUE the screen switches to low brightness ORIENTATION There is no top or bottom when installing the TPS 3000L Press the Orientation button to open the SCREEN SETTINGS ORIENTA...

Page 21: ...imeout respectively Select the Return button to save the timeout setting and return to the SETUP MENU Diagnostics Menu DIAGNOSTICS MENU The Diagnostics button from the MAIN MENU should only be used under supervision from a Crestron customer service representative during telephone support The options available from the DIAGNOSTICS MENU shown to the left are numeric in nature and their interpretatio...

Page 22: ...ation use this port for direct connection between the touchpanel and a PC to load files to a touchpanel without a network connection In the event that modular cables or an RJ11 to DB9F adapter is not available the table below and diagram on the next page provide information so that the cable can be fabricated on site Refer to Appendix RS 232 Protocol on page 46 for protocol details RS 232 Pinouts ...

Page 23: ...nnector provides balanced line level microphone output with AGC A description of the pinouts is shown in the table after this paragraph MIC Pinouts PIN DESIGNATION DESCRIPTION 1 Mic Output Positive 2 Mic Output Negative 3 S Shield AUDIO INPUT This 6 position mini phoenix connector provides line level balanced and unbalanced audio input The pinouts are shown in the tables after this paragraph AUDIO...

Page 24: ...mposite and S video input using BNC connectors or balanced video input using 6 position mini phoenix for video signals Both sets of inputs support both NTSC and PAL formats Balanced video format is typically used when distributing video via CAT 5 i e from a Crestron CNX PVID8x3 or 8x4 Unbalanced video is typically used when distributing video via coaxial cable NOTE Cable runs for balanced video sh...

Page 25: ...Box Kit BB 3000L 6022 Pre Construction Mount Kit PMK 3000L 6024 Mud Mount Kit accessory MMK 3000L 6021 Trim Mount Kit accessory TMK 3000L 6020 Wall Mount Kit Mud WMKM 3000L 6021 Wall Mount Kit Trim WMKT 3000L 6020 Pre construction refers to framed walls prior to hanging drywall Post construction refers to framed walls with drywall hung NOTE There is also a rack mount kit for the TPS 3000L known as...

Page 26: ... 3000L BB 3000L 6 32 x 11 2 SR 06 32 1R5000 2 PAN HEAD SCREW QTY 4 SUPPLIED BY CRESTRON FACEPLATE Optional custom engraved keys can be ordered separately by using the Crestron Engraver Software Version 2 0 0 9 or later is available from the Downloads Software Updates section of the Crestron website www crestron com NOTE If it is necessary to remove the touchpanel secure and label the attached cabl...

Page 27: ...l programming required Crestron AppBuilder completes all necessary programming for a base system including all touchpanel screens and the control system program Once Crestron AppBuilder creates the project the system interfaces and program logic can be customized It can easily be modified with Crestron development tools i e SIMPL Windows and VisionTools Pro e VT Pro e software packages The program...

Page 28: ...amming with the Crestron AppBuilder The easiest method of programming but does not offer as much flexibility as SIMPL Windows Crestron AppBuilder offers automatic programming for such residential and commercial applications as audio distribution home theater video conferencing and lighting The interface of this tool guides you through a few basic steps for designating rooms and specifying the cont...

Page 29: ...y and configure the communications ports Expanded PRO2 System Tree C2Net Device Slot in Configuration Manager To incorporate the TPS 3000L touchpanel into the system drag the TPS 3000 from the Touchpanels Touchpanels Cresnet folder of the Device Library and drop it in the System Views The PRO2 system tree displays the touchpanel in slot 9 with a default NET ID of 03 as shown in the following illus...

Page 30: ... same default NET ID already exists in the program Always ensure that the hardware and software settings of the NET ID match For NET ID hardware settings details refer to Interface Menu on page 13 TPS 3000 Symbol in Programming Manager Programming Manager is where programmers program a Creston control system by assigning signals to symbols The following diagram shows the TPS 3000 symbol in the SIM...

Page 31: ...mmon descriptors are active inactive Analog Signals Unlike digital signals analog signals can vary continuously in value in the same manner as a parameter such as volume temperature or pressure Analog signals contain 16 bits of information which means that this type of signal can have values ranging from 0 to 65535 216 1 This 16 bit property makes analog signals useful for controlling devices that...

Page 32: ...led indirect text Device Extenders Device extenders provide additional logic and functionality to a device The Poll Manager and Sleep Wake Manager symbols are device extenders for touchpanels Poll Manager takes the touchpanel on and off line during polling by the control system Sleep Wake Manager suspends and restores operation of the touchpanel For additional information about Device Extenders re...

Page 33: ...IMPL Windows files that illustrate the high performance capabilities of multi mode objects WAV File Audio Messages The TPS 3000L is capable of playing audio messages as system prompts and responses These files are recorded as WAV files on a PC using an audio utility such as Sound Recorder that is packaged with Microsoft Windows 95 98 Me XP NT 2000 Files from other sources may also be converted to ...

Page 34: ... The join number options include none keyclick or a number 1 through 4000 The default is none If the keyclick option is selected this WAV file becomes the default keyclick sound for all buttons The other WAV files can be played by having the SIMPL Windows program assert the assigned join number 2 Each WAV file must have the correct audio format and attributes for the TPS 3000L target type selected...

Page 35: ...Sound List component shown below permits the designer to attach WAV files to the touchpanel project Complete the following steps to attach add a WAV file Sound List Component 1 Use the Browse button to locate the desired WAV files It should appear in the field adjacent to the Browse button 2 If necessary select the Play button to verify that the file in the browse field is the desired file 3 Selec...

Page 36: ... to right Upright Factory Default and Inverted 5 4 3 2 1 1 2 3 4 5 NOTE A VT Pro e sample project TPS 3000L VTP is available from the VT Pro e section of the Crestron FTP site ftp ftp crestron com VTPro E This project provides guides for panel designers so that they can line up objects with the five quick pushbuttons that flank the LCD display New users are required to register in order to obtain ...

Page 37: ...ameters brightness contrast saturation and hue Video Analog Reserved Join Numbers for the TPS 3000L Touchpanels JOIN FUNCTION VALUE IN OUT 17100 Video Brightness INPUT OUTPUT 17101 Video Contrast INPUT OUTPUT 17102 Video Saturation INPUT OUTPUT 17103 Video Hue INPUT OUTPUT System Digital Reserved Join Numbers for TPS 3000L Touchpanels JOIN FUNCTION VALUE IN OUT 17214 Cresnet ID Down INPUT 17215 Cr...

Page 38: ...s Auto Threshold OUTPUT 17219 System Light Sensor Light Sensor Value OUTPUT Audio Digital Reserved Join Numbers for TPS 3000L Touchpanels JOIN FUNCTION VALUE IN OUT 17300 Audio On INPUT OUTPUT 17301 Audio Off INPUT OUTPUT 17302 Audio Beep On INPUT OUTPUT 17303 Audio Beep Off INPUT OUTPUT 17304 Audio Beep Volume Increase INPUT 17305 Audio Beep Volume Decrease INPUT 17306 Audio Line On INPUT OUTPUT ...

Page 39: ...anels JOIN FUNCTION VALUE IN OUT 17300 Audio Beep Volume INPUT OUTPUT 17301 Audio Line Volume INPUT OUTPUT 17302 Audio Wave Volume INPUT OUTPUT 17305 Audio Bass INPUT OUTPUT 17306 Audio Treble INPUT OUTPUT 17307 Audio Master Volume INPUT OUTPUT Key Feedback Digital Reserved Join Numbers for TPS 3000L Touchpanels JOIN FUNCTION VALUE IN OUT 17904 Key Backlight Brightness Increase INPUT OUTPUT 17905 ...

Page 40: ...string but it is not dynamic Uploading and Upgrading Assuming a PC is properly connected to the entire system Crestron programming software allows the programmer to upload programs and projects to the system and touchpanel after their development However there are times when the files for the program and projects are compiled and not uploaded Instead compiled files may be distributed from programm...

Page 41: ...om a PC refer to the following figure Connect the RS 232 port of the computer directly to the RS 232 port of the touchpanel Refer to page 18 for RS 232 cable information Typical Connection Diagram when Uploading a Project Directly to the Touchpanel RS 232 via Crestron Cable Number STCP 502PC or equivalent 1 Start SIMPL Windows or VT Pro e 2 From the menu bar select Tools Viewport to open the Crest...

Page 42: ...tion parameters and necessary options from the Port Settings window are selected as shown after this step Click the OK button to save the settings and close the window Port Settings Window NOTE Different control systems may require different communication settings Refer to each control system s Operations Guide for proper communication settings 38 6 4 Inch Lectern Wall Mount Touchpanel Crestron Is...

Page 43: ...Windows 1 Start SIMPL Windows 2 Select File Open to view the Open window navigate to the SIMPL Window file smw and click Open 3 Select Project Transfer Program Upload via Crestron Viewport 1 Verify that the procedure for Communication Settings that begins on page 37 has been performed 2 As shown after this step select File Transfer Send Program alternatively press Alt P from the Viewport menu File...

Page 44: ...file has the extension vtz The VT Pro e file can be uploaded to the touchpanel using VT Pro e or via the Crestron Viewport Upload via VT Pro e 1 Start VT Pro e 2 Select File Open Project to view the Open window navigate to the VT Pro e file vtp and click Open 3 Select File Upload Project Upload via Crestron Viewport 1 Verify that the procedure for Communication Settings that begins on page 37 has ...

Page 45: ...ch Panel Transfer Window Each time a project is selected using the Browse command that project is added to the File Name drop down list This makes it convenient to recall projects without need to browse to a directory To delete the list click Clear History All Files in Project sends the entire project Only Changed Files sends only the files that are different from those that are currently stored i...

Page 46: ...the latest version of firmware Not every product has a firmware upgrade but as Crestron improves functions adds new features and extends the capabilities of its products firmware upgrades are posted To upgrade the firmware complete the following steps 1 Make sure that Communication Settings that begins on page 37 has been performed 2 As shown after this step select File Transfer Update Touchpanel ...

Page 47: ...twork ID Window Check Send Direct to Wired Touchpanel if connected via RS 232 directly to touchpanel Select CSF File 4 Browse to the csf file and click Open to begin the transfer Operations Guide DOC 6077 6 4 Inch Lectern Wall Mount Touchpanel Crestron Isys TPS 3000L 43 ...

Page 48: ...the screen to remove the message and enter Performance Viewport via SIMPL Windows or VT Pro e to poll the network Verify that the Cresnet ID for the touchpanel is properly set to match the Net ID in the SIMPL program Touchpanel is not responding Touchpanel Cresnet ID is not unique two or more units share the same ID Enter Performance Viewport via SIMPL Windows or VT Pro e to poll the network and v...

Page 49: ... 2160 In Australia and New Zealand call Crestron Pacific at 613 9480 2999 Future Updates As Crestron improves functions adds new features and extends the capabilities of the TPS 3000 additional information may be made available as manual updates These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision Check the Cr...

Page 50: ...nators When the touchpanel sends a line it is always terminated with cr lf For all strings the first character determines command type Numeric arguments if present are in decimal and separated by commas No control characters are embedded in the strings to ease processing the strings with high level languages Be careful when using commas in BASIC because BASIC uses commas for field separators when ...

Page 51: ...han 2400 baud Obviously ramping several objects at once requires a baud rate several times as high Indirect Text TPS 3000L touchpanels support a feature that permits the text field in any user defined button to be altered on the fly in RUN mode This is accomplished by substituting a text pointer for the text in the button The text pointer informs the panel to use the contents of a variable that ma...

Page 52: ...data or instructions from or to another computer b for local campus or wide area network internet or web hosting services or c pursuant to any rental sharing or service bureau arrangement The Software is designed as a software development and customization tool As such Crestron cannot and does not guarantee any results of use of the Software or that the Software will operate error free and You ack...

Page 53: ... 90 days from the date of receipt and b that any hardware accompanying the Software will be subject to its own limited warranty as stated in its accompanying written material Crestron shall at its option repair or replace or refund the license fee for any Software found defective by Crestron if notified by you within the warranty period The foregoing remedy shall be your exclusive remedy for any c...

Page 54: ...This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been subjected to misuse acc...

Page 55: ...Crestron Isys TPS 3000L 6 4 Lectern Wall Mounted Touchpanel Operations Guide DOC 6077 6 4 Inch Lectern Wall Mount Touchpanel Crestron Isys TPS 3000L 51 This page intentionally left blank ...

Page 56: ...Crestron Electronics Inc Operations Guide DOC 6077 15 Volvo Drive Rockleigh NJ 07647 12 02 Tel 888 CRESTRON Fax 201 767 7576 Specifications subject to www crestron com change without notice ...

Reviews: