background image

Power Switching Cabinet GLPX-HSW-FT  

CRESTRON GREEN LIGHT

®

 EXPRESS

 

Return and Warranty Policies 

Merchandise Returns / Repair Service 

1.  No merchandise may be returned for credit, exchange or service without prior authorization from 

CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized 
CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory and request an 
RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the 
problem, name and phone number of contact person, RMA number and return address. 

2.  Products may be returned for credit, exchange or service with a CRESTRON Return Merchandise 

Authorization (RMA) number. Authorized returns must be shipped freight prepaid to 
CRESTRON, 6 Volvo Drive, Rockleigh, N.J. or its authorized subsidiaries, with RMA number 
clearly marked on the outside of all cartons. Shipments arriving freight collect or without an RMA 
number shall be subject to refusal. CRESTRON reserves the right in its sole and absolute 
discretion to charge a 15% restocking fee plus shipping costs on any products returned with an 
RMA. 

3.  Return freight charges following repair of items under warranty shall be paid by CRESTRON, 

shipping by standard ground carrier. In the event repairs are found to be non-warranty, return 
freight costs shall be paid by the purchaser. 

CRESTRON Limited Warranty 

CRESTRON ELECTRONICS, Inc. warrants its products to be free from manufacturing defects in materials and 
workmanship under normal use for a period of three (3) years from the date of purchase from CRESTRON, 
with the following exceptio

ing mechanical parts, pan/tilt heads and 

power supplies are covered

lay and overlay components are 

covered for 90 days; batteries and incandescent lamps are not covered.  

This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer. 
Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, if any. 

CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any 
application other than that for which it was intended or if it has been subjected to misuse, accidental damage, 
modification or improper installation procedures. Furthermore, this warranty does not cover any product that 
has had the serial number altered, defaced or removed. 

This warranty shall be the sole and exclusive remedy to the original purchaser. In no event shall CRESTRON 
be liable for incidental or consequential damages of any kind (property or economic damages inclusive) arising 
from the sale or use of this equipment. CRESTRON is not liable for any claim made by a third party or made by 
the purchaser for a third party. 

CRESTRON shall, at its option, repair or replace any product found defective, without charge for parts or labor. 
Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the unexpired 
portion of the warranty. 

Except as expressly set forth in this warranty, CRESTRON makes no other warranties, expressed or implied, 
nor authorizes any other party to offer any warranty, including any implied warranties of merchantability or 
fitness for a particular purpose. Any implied warranties that may be imposed by law are limited to the terms of 
this limited warranty. This warranty statement supersedes all previous warranties. 

Trademark Information

 

All brand names, product names and trademarks are the sole property of their respective owners. Windows is a registered trademark of 
Microsoft Corporation. Windows95/98/Me/XP/Vista/7 and WindowsNT/2000 are trademarks of Microsoft Corporation. 

 

ns: disk drives and any other moving or rotat

 for a period of one (1) year; touchscreen disp

16  

  GREEN LIGHT

®

 EXPRESS Power Switching Cabinet GLPX-HSW-FT 

Installation Guide – DOC. 6888B 

Summary of Contents for GREEN LIGHT GLPX-HSW-FT

Page 1: ...irements by Underwriters Laboratories Inc Application The following diagram shows CRESTRON GREEN LIGHT EXPRESS power switching cabinets in a lighting application that is controlled by an IPAC system CRESTRON GREEN LIGHT EXPRESS Power Switching Cabinets in a Typical Lighting Application C R E S N E T O V E R R I D E C R E S N E T C O N T R O L C R E S N E T Crestron Electronics Inc Installation Gui...

Page 2: ...wer switching cabinets Dimensions of GLPX HSW FT 8 12 16 Power Switching Cabinets Front Side and Bottom View 24 1 4 616 mm 16 1 8 409 mm 3 1 16 78 mm KNOCKOUT FOR 3 4 20 mm CONDUIT TYPICAL BOTH SIDES 4 7 16 113 mm 1 4 7 mm 3 1 4 83 mm 2 1 2 64 mm 14 3 8 365 mm 1 1 4 32 mm 2 GREEN LIGHT EXPRESS Power Switching Cabinet GLPX HSW FT Installation Guide DOC 6888B ...

Page 3: ...1 mm 2X Ø 7 16 12 MOUNTING HOLES Ø mm 2x 11 16 19 mm 2 1 8 55 mm 2x Ø 5 8 Ø 16 mm 2X Ø 5 16 Ø 8 mm 58 mm 2 1 4 10 7 8 MOUNTING HOLES 276 mm TIE WRAP HOLDERS MAY BE MOVED TO OTHER HOLES AS REQUIRED SERVICE SCREWDRIVER Installed GLXP modules come with additional tie wrap holders Installation Guide DOC 6888B GREEN LIGHT EXPRESS Power Switching Cabinet GLPX HSW FT 3 ...

Page 4: ...32 Power Switching Cabinets Front Side and Bottom View 16 1 8 409 mm 39 5 8 1 m 3 1 16 78 mm KNOCKOUT FOR 3 4 20 mm CONDUIT TYPICAL BOTH SIDES 4 7 16 113 mm 1 4 7 mm 3 1 4 83 mm 2 1 2 64 mm 14 3 8 365 mm 1 1 4 32 mm 4 GREEN LIGHT EXPRESS Power Switching Cabinet GLPX HSW FT Installation Guide DOC 6888B ...

Page 5: ...m MOUNTING HOLES 2x 11 16 19 mm 10 7 8 276 mm 2 1 4 58 mm GROUND LUG 38 7 8 998 mm 34 3 8 873 mm 2X Ø 7 16 Ø 12 mm MOUNTING HOLES 2x Ø 5 8 Ø 16 mm SERVICE SCREWDRIVER TIE WRAP HOLDERS MAY BE MOVED TO OTHER HOLES AS REQUIRED Installed GLXP modules come with additional tie wrap holders Installation Guide DOC 6888B GREEN LIGHT EXPRESS Power Switching Cabinet GLPX HSW FT 5 ...

Page 6: ...or specific requirements The cabinet is designed for surface mounting on a wall Cabinets are intended for indoor use only The ambient temperature range should be 32 F to 104 F 0 C to 40 C The relative humidity should range from 10 to 90 non condensing Allow adequate clearance in front of the cover for servicing Mounting Location 3 ft 0 9 m Minimum Required Clearance Wall 6 GREEN LIGHT EXPRESS Powe...

Page 7: ...net and N input terminals and connect loads to SW output Connect control wiring section B of the following diagram STRON GREEN LIGHT EXPRESS cabinets are shipped with wing must be performed after mounting th Connect incoming feed conductors to the L terminals section A of the following diagram FEEDS A B CLASS 2 WIRING ONLY FROM BREAKER PANEL TO LOADS FEEDS FROM BREAKER PANEL TO LOADS SERVICE SCREW...

Page 8: ... WIRE RANGE T L AND N INPUTS 26 10 AWG 5 31 lb in 0 6 Nm to 7 08 lb in 0 8 Nm max 3 8 9 mm SW OUTPUTS 26 10 AWG 5 31 lb in 0 6 Nm to 7 08 lb in 0 8 Nm max 3 8 9 mm GROUND LUG 14 4 AWG 25 45 lb in 2 8 5 1 Nm 3 4 19 mm Load Wiring for GLXP HSW8 and GLXP HSW12 TO NEUTRAL TO BRANCH BREAKER TO LOAD JUMPER L CIRCUIT BREAKER 20A MAX NEUTRAL BUS TO LOADS N L GROUND LUG N1 L1 SW1 SERVICE SCREWDRIVER A sing...

Page 9: ...alarm relay etc NOTE Interface connectors for NET x2 POWER x1 and OVERRIDE x3 ports are provided Wire Gauge and Torque Values TERMINAL CONNECTOR MAX TORQUE STRIP WIRE RANGE LENGTH NET 12 AW 43 lb in 5 Nm 26 G 4 0 1 4 6 mm POWER 26 12 AWG 4 43 lb in 0 5 Nm 1 4 6 mm OVERRIDE 26 12 AWG 4 4 0 5 Nm 3 lb in 1 4 6 mm Connector Wiring RED WHITE BLUE BLACK NET TO CONTROL SYSTEM AND OTHER CRESNET DEVICES RE...

Page 10: ...o power the modules from the NET port in per from th n on the supplied POWER he EXT pin on the POWER connector as shown in the following diagram Providing Cresnet Power Via The Net Port of using improper wire conductors Twist together into the Cre net connector tighten th ning screw R PO Each m voltage power m available the ied to t ve power vi r internally vi low volta T port or supply connected ...

Page 11: ...ED extinguishes and the outputs return to the states set by the control system program NOTE If override states have not been stored the factory default override state is all loads on Save Override Settings The mod NO an prevent locally saving the override state If this setting is state of each output can be saved as an override setting which can be automatically recalled when the Override e is ena...

Page 12: ...ion but will draw power from the has not tripped Note that unit will continue backup Cresnet power supply if available Unit cannot be taken out Short contact closure of Override mode exists between G and OVR terminals on any of the OVERRIDE terminals present at bottom of the cabinet Determine the reason for the short Remove or remedy the short e g GLS PLS 120 277 phase loss sensor may not phase lo...

Page 13: ...form this step if instructed by an authorized Crestron representative or when replacing modules on a system that have already been commissioned in the latter case the Net ID should be set to match the Net ID of the module being replaced The Net ID of ea the system m e set the Net ID using th 1 Press anel P button to ente The SETUP LED illuminates nder the NET ID display to change t isplay to chang...

Page 14: ... 277 VAC 50 60 Hz Supported Load Types Incandescent HID magnetic low voltage MLV electronic low voltage ELV neon cold cathode and fluorescent ballasts motor Maximum Load Lighting 16 A per output t Mo or HP 120V 1 HP 230V 277V Environmental Temperature 32º to 104º F 0º to 40º C Humidity 10 to 90 RH non condensing Heat Dissipation 10 BTU Hr 14 GREEN LIGHT EXPRESS Power Switching Cabinet GLPX HSW FT ...

Page 15: ...CRESTRON GREEN LIGHT EXPRESS Power Switching Cabinet GLPX HSW FT This page is intentionally left blank Installation Guide DOC 6888B GREEN LIGHT EXPRESS Power Switching Cabinet GLPX HSW FT 15 ...

Page 16: ...cts purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been subjected to misuse accidental damage modification or...

Reviews: