background image

GREEN LIGHT

®

 EXPRESS Power Switching Cabinet GLPX-HSW-FT

 

Introduction 

CRESTRON GREEN LIGHT EXPRESS power switching cabinets come pre-configured with GLXP switching 
modules already installed. The cabinets only require installation and wiring of feed and load circuits. 

Regulatory Compliance 

The cabinet and modules are Listed to applicable UL Standar

  

ds and requirements by Underwriters Laboratories Inc.

 

 

Application 

The following diagram shows CRESTRON GREEN LIGHT EXPRESS power switching cabinets in a lighting 
application that is controlled by an IPAC system. 

CRESTRON GREEN LIGHT EXPRESS Power Switching Cabinets in a Typical Lighting Application 

C

R

E

S

N

E

T

O

V

E

R

R

I

D

E

C

R

E

S

N

E

T

C

O

N

T

R

O

L

C

R

E

S

N

E

T

 

Crestron Electronics, Inc.

 

Installation Guide – DOC. 6888B

 

15 Volvo Drive   Rockleigh, NJ 07647

 

(2025419)

 

Tel: 888.CRESTRON

 

06.10

 

Fax: 201.767.7576

  

Specifications subject to 

 

www.crestron.com

 

change without notice.

 

Summary of Contents for GREEN LIGHT GLPX-HSW-FT

Page 1: ...irements by Underwriters Laboratories Inc Application The following diagram shows CRESTRON GREEN LIGHT EXPRESS power switching cabinets in a lighting application that is controlled by an IPAC system CRESTRON GREEN LIGHT EXPRESS Power Switching Cabinets in a Typical Lighting Application C R E S N E T O V E R R I D E C R E S N E T C O N T R O L C R E S N E T Crestron Electronics Inc Installation Gui...

Page 2: ...wer switching cabinets Dimensions of GLPX HSW FT 8 12 16 Power Switching Cabinets Front Side and Bottom View 24 1 4 616 mm 16 1 8 409 mm 3 1 16 78 mm KNOCKOUT FOR 3 4 20 mm CONDUIT TYPICAL BOTH SIDES 4 7 16 113 mm 1 4 7 mm 3 1 4 83 mm 2 1 2 64 mm 14 3 8 365 mm 1 1 4 32 mm 2 GREEN LIGHT EXPRESS Power Switching Cabinet GLPX HSW FT Installation Guide DOC 6888B ...

Page 3: ...1 mm 2X Ø 7 16 12 MOUNTING HOLES Ø mm 2x 11 16 19 mm 2 1 8 55 mm 2x Ø 5 8 Ø 16 mm 2X Ø 5 16 Ø 8 mm 58 mm 2 1 4 10 7 8 MOUNTING HOLES 276 mm TIE WRAP HOLDERS MAY BE MOVED TO OTHER HOLES AS REQUIRED SERVICE SCREWDRIVER Installed GLXP modules come with additional tie wrap holders Installation Guide DOC 6888B GREEN LIGHT EXPRESS Power Switching Cabinet GLPX HSW FT 3 ...

Page 4: ...32 Power Switching Cabinets Front Side and Bottom View 16 1 8 409 mm 39 5 8 1 m 3 1 16 78 mm KNOCKOUT FOR 3 4 20 mm CONDUIT TYPICAL BOTH SIDES 4 7 16 113 mm 1 4 7 mm 3 1 4 83 mm 2 1 2 64 mm 14 3 8 365 mm 1 1 4 32 mm 4 GREEN LIGHT EXPRESS Power Switching Cabinet GLPX HSW FT Installation Guide DOC 6888B ...

Page 5: ...m MOUNTING HOLES 2x 11 16 19 mm 10 7 8 276 mm 2 1 4 58 mm GROUND LUG 38 7 8 998 mm 34 3 8 873 mm 2X Ø 7 16 Ø 12 mm MOUNTING HOLES 2x Ø 5 8 Ø 16 mm SERVICE SCREWDRIVER TIE WRAP HOLDERS MAY BE MOVED TO OTHER HOLES AS REQUIRED Installed GLXP modules come with additional tie wrap holders Installation Guide DOC 6888B GREEN LIGHT EXPRESS Power Switching Cabinet GLPX HSW FT 5 ...

Page 6: ...or specific requirements The cabinet is designed for surface mounting on a wall Cabinets are intended for indoor use only The ambient temperature range should be 32 F to 104 F 0 C to 40 C The relative humidity should range from 10 to 90 non condensing Allow adequate clearance in front of the cover for servicing Mounting Location 3 ft 0 9 m Minimum Required Clearance Wall 6 GREEN LIGHT EXPRESS Powe...

Page 7: ...net and N input terminals and connect loads to SW output Connect control wiring section B of the following diagram STRON GREEN LIGHT EXPRESS cabinets are shipped with wing must be performed after mounting th Connect incoming feed conductors to the L terminals section A of the following diagram FEEDS A B CLASS 2 WIRING ONLY FROM BREAKER PANEL TO LOADS FEEDS FROM BREAKER PANEL TO LOADS SERVICE SCREW...

Page 8: ... WIRE RANGE T L AND N INPUTS 26 10 AWG 5 31 lb in 0 6 Nm to 7 08 lb in 0 8 Nm max 3 8 9 mm SW OUTPUTS 26 10 AWG 5 31 lb in 0 6 Nm to 7 08 lb in 0 8 Nm max 3 8 9 mm GROUND LUG 14 4 AWG 25 45 lb in 2 8 5 1 Nm 3 4 19 mm Load Wiring for GLXP HSW8 and GLXP HSW12 TO NEUTRAL TO BRANCH BREAKER TO LOAD JUMPER L CIRCUIT BREAKER 20A MAX NEUTRAL BUS TO LOADS N L GROUND LUG N1 L1 SW1 SERVICE SCREWDRIVER A sing...

Page 9: ...alarm relay etc NOTE Interface connectors for NET x2 POWER x1 and OVERRIDE x3 ports are provided Wire Gauge and Torque Values TERMINAL CONNECTOR MAX TORQUE STRIP WIRE RANGE LENGTH NET 12 AW 43 lb in 5 Nm 26 G 4 0 1 4 6 mm POWER 26 12 AWG 4 43 lb in 0 5 Nm 1 4 6 mm OVERRIDE 26 12 AWG 4 4 0 5 Nm 3 lb in 1 4 6 mm Connector Wiring RED WHITE BLUE BLACK NET TO CONTROL SYSTEM AND OTHER CRESNET DEVICES RE...

Page 10: ...o power the modules from the NET port in per from th n on the supplied POWER he EXT pin on the POWER connector as shown in the following diagram Providing Cresnet Power Via The Net Port of using improper wire conductors Twist together into the Cre net connector tighten th ning screw R PO Each m voltage power m available the ied to t ve power vi r internally vi low volta T port or supply connected ...

Page 11: ...ED extinguishes and the outputs return to the states set by the control system program NOTE If override states have not been stored the factory default override state is all loads on Save Override Settings The mod NO an prevent locally saving the override state If this setting is state of each output can be saved as an override setting which can be automatically recalled when the Override e is ena...

Page 12: ...ion but will draw power from the has not tripped Note that unit will continue backup Cresnet power supply if available Unit cannot be taken out Short contact closure of Override mode exists between G and OVR terminals on any of the OVERRIDE terminals present at bottom of the cabinet Determine the reason for the short Remove or remedy the short e g GLS PLS 120 277 phase loss sensor may not phase lo...

Page 13: ...form this step if instructed by an authorized Crestron representative or when replacing modules on a system that have already been commissioned in the latter case the Net ID should be set to match the Net ID of the module being replaced The Net ID of ea the system m e set the Net ID using th 1 Press anel P button to ente The SETUP LED illuminates nder the NET ID display to change t isplay to chang...

Page 14: ... 277 VAC 50 60 Hz Supported Load Types Incandescent HID magnetic low voltage MLV electronic low voltage ELV neon cold cathode and fluorescent ballasts motor Maximum Load Lighting 16 A per output t Mo or HP 120V 1 HP 230V 277V Environmental Temperature 32º to 104º F 0º to 40º C Humidity 10 to 90 RH non condensing Heat Dissipation 10 BTU Hr 14 GREEN LIGHT EXPRESS Power Switching Cabinet GLPX HSW FT ...

Page 15: ...CRESTRON GREEN LIGHT EXPRESS Power Switching Cabinet GLPX HSW FT This page is intentionally left blank Installation Guide DOC 6888B GREEN LIGHT EXPRESS Power Switching Cabinet GLPX HSW FT 15 ...

Page 16: ...cts purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been subjected to misuse accidental damage modification or...

Reviews: