background image

FlipTop Power Center 

Crestron 

FT-PWR-B & FT-PWR-BALUM

 

 Return and Warranty Policies 

Merchandise Returns / Repair Service 

1.  No merchandise may be returned for credit, exchange, or service without prior authorization 

from CRESTRON. To obtain warranty service for CRESTRON products, contact an 
authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory 
and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying 
the nature of the problem, name and phone number of contact person, RMA number, and 
return address. 

2.  Products may be returned for credit, exchange, or service with a CRESTRON Return 

Merchandise Authorization (RMA) number. Authorized returns must be shipped freight 
prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N.J. or its authorized subsidiaries, with 
RMA number clearly marked on the outside of all cartons. Shipments arriving freight collect 
or without an RMA number shall be subject to refusal. CRESTRON reserves the right in its 
sole and absolute discretion to charge a 15% restocking fee, plus shipping costs, on any 
products returned with an RMA. 

3.  Return freight charges following repair of items under warranty shall be paid by CRESTRON, 

shipping by standard ground carrier. In the event repairs are found to be non-warranty, return 
freight costs shall be paid by the purchaser. 

CRESTRON Limited Warranty 

CRESTRON ELECTRONICS, Inc. warrants its products to be free from manufacturing defects in materials 
and workmanship under normal use for a period of three (3) years from the date of purchase from 
CRESTRON, with the following exceptions: disk drives and any other moving or rotating mechanical 
parts, pan/tilt heads and power supplies are covered for a period of one (1) year; touchscreen display and 
overlay components are covered for 90 days; batteries and incandescent lamps are not covered.  
This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON 
dealer. Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, if 
any. 
CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any 
application other than that for which it was intended, or if it has been subjected to misuse, accidental 
damage, modification, or improper installation procedures. Furthermore, this warranty does not cover any 
product that has had the serial number altered, defaced, or removed.  
This warranty shall be the sole and exclusive remedy to the original purchaser. In no event shall 
CRESTRON be liable for incidental or consequential damages of any kind (property or economic damages 
inclusive) arising from the sale or use of this equipment. CRESTRON is not liable for any claim made by a 
third party or made by the purchaser for a third party.  
CRESTRON shall, at its option, repair or replace any product found defective, without charge for parts or 
labor. Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the 
unexpired portion of the warranty. 
Except as expressly set forth in this warranty, CRESTRON makes no other warranties, expressed or 
implied, nor authorizes any other party to offer any warranty, including any implied warranties of 
merchantability or fitness for a particular purpose. Any implied warranties that may be imposed by law are 
limited to the terms of this limited warranty. This warranty statement supersedes all previous warranties. 

Trademark Information

 

All brand names, product names, and trademarks are the sole property of their respective owners. Windows is a registered trademark 
of Microsoft Corporation. Windows95/98/Me/XP and WindowsNT/2000 are trademarks of Microsoft Corporation. 

14  

  FlipTop Power Center FT-PWR-B & FT-PWR-BALUM 

Operations & Installation Guide – DOC. 6480 

Summary of Contents for FT-PWR

Page 1: ...Crestron FT PWR B FT PWR BALUM FlipTopPowerCenter Operations Installation Guide...

Page 2: ...by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respectiv...

Page 3: ...ations 1 Specifications 2 Physical Description 2 Industry Compliance 6 Setup 7 Installation 7 Hardware Hookup 11 Operation 12 Problem Solving 13 Troubleshooting 13 Further Inquiries 13 Future Updates...

Page 4: ......

Page 5: ...d FT PWR B or brushed aluminum FT PWR BALUM Applications The FT PWR B and FT PWR BALUM provide an elegant connectivity solution in a stylish flush mount tabletop package Beneath the FlipTop lid the ca...

Page 6: ...ck painted metal with black anodized or brushed aluminum cover flush tabletop mountable Dimensions Height 5 33 in 13 54 cm with lid closed Width 6 75 in 17 15 cm Depth 5 71 in 14 50 cm Weight 3 75 lbs...

Page 7: ...LUM Overall Dimensions Top View 6 61 in 16 79 cm 6 75 in 17 15 cm 5 71 in 14 50 cm 5 08 in 12 90 cm FT PWR B and FT PWR BALUM Overall Dimensions Front View 5 38 in 13 67 cm 6 25 in 15 88 cm Operations...

Page 8: ...B FT PWR BALUM FT PWR B and FT PWR BALUM Overall Dimensions Side View 5 33 in 13 54 cm 2 38 in 6 05 cm 4 56 in 11 58 cm 4 64 in 11 79 cm 5 21 in 13 32 cm 4 FlipTop Power Center FT PWR B FT PWR BALUM O...

Page 9: ...ION 1 120 VAC 50 60 Hz 10 amperes Maximum Load This 3 prong grounded AC input socket is connected to a line cord located on the bottom side 2 This is a grounded AC line cord 125 VAC at 60 Hz Connect t...

Page 10: ...ainst harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may caus...

Page 11: ...inch 0 64 cm L 4 The cable support plate should be installed before mounting the FT PWR B or FT PWR BALUM to a surface The cables are looped through the cable support plate 1 Place bushings on the cab...

Page 12: ...OTE Ensure that any cables you install have sufficient clearance to enable smooth movement Mounting to Surface The FT PWR B and FT PWR BALUM are designed to mount in a horizontal surface such as a des...

Page 13: ...BALUM Mounting Parts Supplied PART DESCRIPTION QUANTITY Screw 6 32 3 16 L Pan Head Phillips 8 Screw 10 32 2 L Pan Head Phillips 4 Mounting Bracket 2 1 Install the eight supplied 6 32 screws but do no...

Page 14: ...the following diagram 4 Slide the mounting brackets over the 6 32 screws and tighten the 6 32 screws Mounting Bracket Installation 5 Turn the four 10 screws equally until they contact the underside of...

Page 15: ...given if installed inside a closed desk or in a closed podium since the operating ambient temperature of these environments may be greater than the room ambient Contact with thermal insulating materi...

Page 16: ...s 135 degrees allowing full access to cables and power inside Beneath the lid a recessed compartment with eight grommeted holes through the bottom plate allows any type of AV communication data or con...

Page 17: ...273 7876 For assistance in your local time zone refer to the Crestron website http www crestron com for a listing of Crestron worldwide offices You can also log onto the online help section of the Cr...

Page 18: ...0 days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer rega...

Page 19: ...Crestron FT PWR B FT PWR BALUM FlipTop Power Center Operations Installation Guide DOC 6480 FlipTop Power Center FT PWR B FT PWR BALUM 15 This page is intentionally left blank...

Page 20: ...ron Electronics Inc Operations Installation Guide DOC 6480 15 Volvo Drive Rockleigh NJ 07647 2014987 Tel 888 CRESTRON 05 06 Fax 201 767 7576 Specifications subject to www crestron com change without n...

Reviews: