Industry Compliance 

As of the date of manufacture, the FT-PWR-B and FT-PWR-BALUM have been 
tested and found to comply with specifications for CE marking and standards per 
EMC and Radiocommunications Compliance Labelling. 

      

 

NOTE:  

This device complies with part 15 of the FCC rules. Operation is subject to 

the following two conditions: (1) this device may not cause harmful interference, and 
(2) this device must accept any interference received, including interference that may 
cause undesired operation.  

This equipment has been tested and found to comply with the limits for a Class B 
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection against harmful interference in a residential 
installation. This equipment generates, uses and can radiate radio frequency energy 
and, if not installed and used in accordance with the instructions, may cause harmful 
interference to radio communications. However, there is no guarantee that 
interference will not occur in a particular installation. If this equipment does cause 
harmful interference to radio or television reception, which can be determined by 
turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures: 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

 

Connect the equipment into an outlet on a circuit different from that to 
which the receiver is connected. 

 

Consult the dealer or an experienced radio/TV technician for help. 

6  

  FlipTop Power Center FT-PWR-B & FT-PWR-BALUM 

Operations & Installation Guide – DOC. 6480 

Summary of Contents for FT-PWR

Page 1: ...Crestron FT PWR B FT PWR BALUM FlipTopPowerCenter Operations Installation Guide...

Page 2: ...by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respectiv...

Page 3: ...ations 1 Specifications 2 Physical Description 2 Industry Compliance 6 Setup 7 Installation 7 Hardware Hookup 11 Operation 12 Problem Solving 13 Troubleshooting 13 Further Inquiries 13 Future Updates...

Page 4: ......

Page 5: ...d FT PWR B or brushed aluminum FT PWR BALUM Applications The FT PWR B and FT PWR BALUM provide an elegant connectivity solution in a stylish flush mount tabletop package Beneath the FlipTop lid the ca...

Page 6: ...ck painted metal with black anodized or brushed aluminum cover flush tabletop mountable Dimensions Height 5 33 in 13 54 cm with lid closed Width 6 75 in 17 15 cm Depth 5 71 in 14 50 cm Weight 3 75 lbs...

Page 7: ...LUM Overall Dimensions Top View 6 61 in 16 79 cm 6 75 in 17 15 cm 5 71 in 14 50 cm 5 08 in 12 90 cm FT PWR B and FT PWR BALUM Overall Dimensions Front View 5 38 in 13 67 cm 6 25 in 15 88 cm Operations...

Page 8: ...B FT PWR BALUM FT PWR B and FT PWR BALUM Overall Dimensions Side View 5 33 in 13 54 cm 2 38 in 6 05 cm 4 56 in 11 58 cm 4 64 in 11 79 cm 5 21 in 13 32 cm 4 FlipTop Power Center FT PWR B FT PWR BALUM O...

Page 9: ...ION 1 120 VAC 50 60 Hz 10 amperes Maximum Load This 3 prong grounded AC input socket is connected to a line cord located on the bottom side 2 This is a grounded AC line cord 125 VAC at 60 Hz Connect t...

Page 10: ...ainst harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may caus...

Page 11: ...inch 0 64 cm L 4 The cable support plate should be installed before mounting the FT PWR B or FT PWR BALUM to a surface The cables are looped through the cable support plate 1 Place bushings on the cab...

Page 12: ...OTE Ensure that any cables you install have sufficient clearance to enable smooth movement Mounting to Surface The FT PWR B and FT PWR BALUM are designed to mount in a horizontal surface such as a des...

Page 13: ...BALUM Mounting Parts Supplied PART DESCRIPTION QUANTITY Screw 6 32 3 16 L Pan Head Phillips 8 Screw 10 32 2 L Pan Head Phillips 4 Mounting Bracket 2 1 Install the eight supplied 6 32 screws but do no...

Page 14: ...the following diagram 4 Slide the mounting brackets over the 6 32 screws and tighten the 6 32 screws Mounting Bracket Installation 5 Turn the four 10 screws equally until they contact the underside of...

Page 15: ...given if installed inside a closed desk or in a closed podium since the operating ambient temperature of these environments may be greater than the room ambient Contact with thermal insulating materi...

Page 16: ...s 135 degrees allowing full access to cables and power inside Beneath the lid a recessed compartment with eight grommeted holes through the bottom plate allows any type of AV communication data or con...

Page 17: ...273 7876 For assistance in your local time zone refer to the Crestron website http www crestron com for a listing of Crestron worldwide offices You can also log onto the online help section of the Cr...

Page 18: ...0 days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer rega...

Page 19: ...Crestron FT PWR B FT PWR BALUM FlipTop Power Center Operations Installation Guide DOC 6480 FlipTop Power Center FT PWR B FT PWR BALUM 15 This page is intentionally left blank...

Page 20: ...ron Electronics Inc Operations Installation Guide DOC 6480 15 Volvo Drive Rockleigh NJ 07647 2014987 Tel 888 CRESTRON 05 06 Fax 201 767 7576 Specifications subject to www crestron com change without n...

Reviews: