Crestron
e-Control
®
Software
As shown in the previous diagram, you can click
Apply Settings to All Pages
to set
the same IP information to all the pages in the browser project. You can also click the
Virtual feedback
check box if you want to enable “instant” feedback. This feature
causes an object such as a button to display in its active state the moment the user
clicks it, even if there is some delay in receiving actual feedback from the controlled
device.
SIMPL Windows Programming (Java and XPANEL)
For each IP ID you set in the VT Pro-e browser project, you must define one
e-
Control PC Interface
symbol in the SIMPL Windows program. (If you assign the
same IP ID to all the pages in the browser project, you need to define just one PC
Interface symbol.) The PC Interface symbol is located in the Ethernet Modules folder
of the Device Library and the symbol detail is defined identically to a touchpanel
symbol. That is, all the join numbers you define in the VT Pro-e project map to signals
on the symbol detail.
To configure the symbol, open the SIMPL Windows Configuration Manager screen:
1. Drag the e-Control PC Interface symbol from the Device Library to the
Ethernet slot on the control system. Double-click the symbol to open the
Device Settings
dialog box.
2. Click
the
IP Net Address
tab and select the same IP ID that was set for the
HTML pages in the VT Pro-e browser project. Then enter the IP address of
the machine where the e-Control gateway resides. If the gateway is the
internal “hardware” gateway, the IP address is 127.0.0.1. If the gateway is the
CNX-EGWY, the IP address is the address of the PC.
3. When you bring the PC Interface symbol to
Detail View
in Program Manager,
you have to map the previously defined join numbers to inputs and outputs on
the symbol.
Reference Guide – DOC. 6052
Crestron e-Control®
•
35