Page 1: ...Crestron DM RMC 200 S S2 DigitalMedia8G FiberReceiver RoomController200 Operations Installation Guide ...

Page 2: ... within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPA...

Page 3: ...dance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense WARNING Visible and invisible laser radiation when open Avoid direct exposure to beam NOTE Plug the included dust cap into the optical...

Page 4: ......

Page 5: ...7 Network Wiring 17 Identity Code 17 Supplied Hardware 18 Installation 18 Hardware Hookup 21 Programming Software 23 Software Requirements for the PC 23 Programming with SIMPL Windows 23 Uploading and Upgrading 26 Establishing Communication 26 Firmware 29 IP Configuration 29 Problem Solving 30 Troubleshooting 30 Reference Documents 31 Further Inquiries 31 Future Updates 32 Return and Warranty Poli...

Page 6: ......

Page 7: ...r and display controller DM 8G fiber input supports up to 1000 foot 300 meter cable length DM RMC 200 S 1 DM 8G SM fiber input supports up to 7 5 miles 12 km cable length DM RMC 200 S2 1 Connects to a DM switcher or transmitter each sold separately over one multimode DM RMC 200 S single mode DM RMC 200 S2 fiber strand1 Provides one HDMI or DVI display output2 Accepts any video source from standard...

Page 8: ...able without compression or repeaters Engineered for ultra high bandwidth and ultimate scalability DM 8G handles uncompressed video beyond high definition with support for HDCP Deep Color and 3D1 Audio capabilities include support for high bitrate 7 1 audio formats such as Dolby TrueHD and DTS HD Master Audio as well as uncompressed linear PCM All DM RMC 200 S signals are transported over one stra...

Page 9: ...well as computer sources from VGA to UXGA WUXGA and scales them perfectly to match the native resolution of the video display A range of common output resolutions is supported to work with virtually any popular flat panel display projector or computer monitor Intelligent frame rate conversion enables support for 24p and PAL format sources and 3D to 2D conversion allows 3D content to be fed simulta...

Page 10: ... at the central equipment rack or some other location Embedded Device Control The DM receiver includes built in RS 232 IR and Ethernet control ports to allow programmable control of the display device connected to it It can also provide an alternative to such conventional control methods by harnessing the CEC Consumer Electronics Control signal embedded in HDMI Through its connection to the contro...

Page 11: ...G fiber transmitter such as the DM TX 201 S sold separately and is not used with a DM switcher DM RMC 200 S in a Standalone Application In a DM RMC 200 S2 standalone application the DM RMC 200 S2 is used with a DM 8G SM fiber transmitter such as the DM TX 201 S2 sold separately and is not used with a DM switcher Operations Installation Guide DOC 7246B DigitalMedia 8G Fiber Receiver 200 DM RMC 200 ...

Page 12: ...strand 4 Output Signal Types HDMI DVI 5 Formats HDMI with Deep Color 3D 2 DVI HDCP content protection support Input Resolutions Progressive 640 x 480 60 Hz 720 x 480 60 Hz 480p 720 x 576 50 Hz 576p 800 x 600 60 Hz 848 x 480 60 Hz 852 x 480 60 Hz 854 x 480 60 Hz 1024 x 768 60 Hz 1024 x 852 60 Hz 1024 x 1024 60 Hz 1280 x 720 50 Hz 720p50 1280 x 720 60 Hz 720p60 1280 x 768 60 Hz 1280 x 800 60 Hz 1280...

Page 13: ...66 x 768 60 Hz 6 1400 x 1050 60 Hz 6 1440 x 900 60 Hz 6 1600 x 900 60 Hz7 1600 x 1200 60 Hz 1680 x 1050 60 Hz 6 1920 x 1080 50 Hz 1080p50 1920 x 1080 60 Hz 1080p60 1920 x 1200 60 Hz 7 2048 x 1152 60 Hz 7 Interlaced 720 x 480 30 Hz 480i 720 x 576 25 Hz 576i 1920 x 1080 25 Hz 1080i25 1920 x 1080 30 Hz 1080i30 Pass Thru Output Resolutions Matched to input Audio Input Signal Type DM RMC 200 S DM 8G fi...

Page 14: ... Requirements Power Pack 2 A 24 volts dc 100 240 volts ac 50 60 Hz power pack included Minimum 2 Series Control System Update File 9 10 Version 4 003 0029 or later Environmental Temperature 32º to 104º F 0º to 40º C Humidity 10 to 90 RH non condensing Heat Dissipation Power amp off no relay or USB loads 60 Btu h Power amp on with relay and USB loads 80 Btu h maximum Enclosure Chassis Metal black f...

Page 15: ...o wall processing requires a separate DM receiver for each individual display 4 For DM 8G wiring the maximum DigitalMedia 8G fiber cable length is 1000 feet 300 meters using CRESFIBER8G fiber optic cable or 500 feet 150 meters using standard CRESFIBER CRESFIBER SINGLE SC or generic OM3 simplex multimode fiber optic cable For DM 8G SMF wiring up to 7 5 miles 12 km between devices use Crestron CRESF...

Page 16: ...n This section provides information on the connections controls and indicators available on the DM receiver DM RMC 200 S DM RMC 200 S2 Physical View Front Panel DM RMC 200 S DM RMC 200 S2 10 DigitalMedia 8G Fiber Receiver 200 DM RMC 200 S S2 Operations Installation Guide DOC 7246B ...

Page 17: ...00 S DM RMC 200 S2 Physical View Rear Panel DM RMC 200 S DM RMC 200 S2 Physical View Top Panel DM RMC 200 S DM RMC 200 S2 DM RMC 200 S DM RMC 200 S2 Physical View Bottom Panel Operations Installation Guide DOC 7246B DigitalMedia 8G Fiber Receiver 200 DM RMC 200 S S2 11 ...

Page 18: ... 45 in 190 mm 7 92 in 201 mm 7 54 in 192 mm 1 05 in 27 mm 1 46 in 37 mm DM RMC 200 S DM RMC 200 S2 Overall Dimensions Front and Side Panels with Mounting Bracket Installed 1 30 in 33 mm 10 83 in 275 mm 3 30 in 84 mm 4 93 in 126 mm 1 23 in 32 mm 1 53 in 39 mm 1 62 in 41 mm 1 73 in 44 mm 12 DigitalMedia 8G Fiber Receiver 200 DM RMC 200 S S2 Operations Installation Guide DOC 7246B ...

Page 19: ... Panel 5 1 2 3 4 6 DM RMC 200 S DM RMC 200 S2 Connectors Controls Indicators Top Panel 8 7 9 11 12 13 10 DM RMC 200 S DM RMC 200 S2 10 7 8 11 12 DM RMC 200 S DM RMC 200 S2 Connectors Controls Indicators Bottom Panel 14 15 16 17 18 Operations Installation Guide DOC 7246B DigitalMedia 8G Fiber Receiver 200 DM RMC 200 S S2 13 ...

Page 20: ...atus 4 USB HID LED 1 Green LED indicates a valid device connection and activity on the USB HID port 5 SETUP LED and Button 1 Red LED and 1 miniature recessed push button for Ethernet setup 6 RESET 1 Miniature recessed push button for hardware reset 7 AUDIO OUT R L Speaker 2 2 2 pin 5 mm detachable terminal blocks Left and right speaker level audio outputs Paralleled with rear panel AUDIO OUT conne...

Page 21: ...L PIN SIGNAL 1 TX 5 N C 2 TX 6 RX 3 RX 7 N C 4 N C 8 N C 12 24 V 2 0A MAX 1 2 1 x 5 5 mm dc power connector 24 volt dc power input Power pack included 13 DM IN SMF LC DM RMC 200 S2 only 1 LC female optical fiber connector DM 8G single mode fiber input Connects to DM 8G SMF output of a DM switcher transmitter or other DM device via CresFiber 8G SM single mode fiber optic cable 3 14 DIG IN S G 1 2 p...

Page 22: ...ed relays Rated 1 amp 30 volts ac dc MOV arc suppression across contacts 1 Interface connectors for the AUDIO OUT Speaker DIG IN COM IR and RELAY ports are provided with the unit 2 The set of speaker level audio outputs on the top panel and the set of speaker level audio outputs on the rear panel cannot be used simultaneously Either set of speaker level audio outputs should be used at one time 3 F...

Page 23: ...peed Ethernet for communications between the device and a control system computer media server and other IP based devices For general information on connecting Ethernet devices in a Crestron system refer to the latest version of the Crestron e Control Reference Guide Doc 6052 which is available from the Crestron Web site www crestron com manuals For information specifically related to Ethernet con...

Page 24: ...ceeds the environmental temperature range listed in the table of specifications Mounting The DM receiver mounts to a 2 gang electrical box not included To mount the DM receiver perform the following steps refer to the illustration on the following page 1 Attach the four included 06 32 x 1 1 4 standoffs 2007056 to the studs of the included mounting bracket 2032478 2 Using the four included 06 32 x ...

Page 25: ...he included power pack 2022484 To install the power pack perform the following steps refer to the illustration on the following page 1 Slide the power pack 2022484 into the holder 2 Using the two included 06 32 x 1 Phillips head screws 2007250 thread the screws through the two holes on the front of the power pack holder to hold the power pack in place 3 Using the two included tie wraps 2013608 thr...

Page 26: ... Screws 2 06 32 x 1 2007250 Power Pack 2022484 Tie Wrap Holes 2 Power Pack Holder Installation of the power pack in the holder is shown below Power Pack Installed in Holder of Mounting Bracket 20 DigitalMedia 8G Fiber Receiver 200 DM RMC 200 S S2 Operations Installation Guide DOC 7246B ...

Page 27: ...l Audio Output LAN 10BASE T 100BASE TX Ethernet to Local Network Device 24 V 2 0A MAX From Power Pack Included DM IN MMF SC From DM Switcher Transmitter or Other DM Device Hardware Connections for the DM RMC 200 S2 Top Panel AUDIO OUT R L SPEAKER Amplified Stereo Audio Output AUDIO OUT R L LINE Stereo Unbalanced Line Level Audio Output LAN 10BASE T 100BASE TX Ethernet to Local Network Device 24 V ...

Page 28: ...re that the unit is properly grounded by connecting the chassis ground lug to an earth ground building steel NOTE Do not connect the set of speaker level audio outputs on the top panel and the set of speaker level audio outputs on the rear panel simultaneously Only one set of speaker level audio outputs can be used at one time NOTE For optimum performance Crestron recommends using CresFiber 8G fib...

Page 29: ...PL Windows to create a program to control the DM receiver Programming with SIMPL Windows SIMPL Windows is Crestron s premier software for programming Crestron control systems It is organized into two separate but equally important Managers Configuration and Program Configuration Manager Configuration Manager is the view where programmers build a Crestron control system by selecting hardware from t...

Page 30: ...ENET 2 card in an Ethernet slot on the control system C2ENET 2 Device Slot 8 Using Output Card in a DM Switcher C2ENET 2 Device Slot 8 Using Ethernet Slot on Control System 2 If additional DM receivers are to be added repeat step 1 for each device Each DM receiver is assigned a different IP ID 3 If necessary double click a device to open the Device Settings window and change the IP ID as shown in ...

Page 31: ...n page 17 Program Manager Program Manager is the view where programmers program a Crestron control system by assigning signals to symbols The symbol can be viewed by double clicking the icon or dragging it into Detail View Each signal in the symbol is described in the SIMPL Windows help file F1 Operations Installation Guide DOC 7246B DigitalMedia 8G Fiber Receiver 200 DM RMC 200 S S2 25 ...

Page 32: ...mmunicates with the DM receiver in the following ways Via a DM switcher using TCP IP or USB communication TCP IP provides a faster method of communication than USB Via the LAN port of the DM receiver using TCP IP communication In this scenario the DM receiver is used in a standalone configuration i e a DM switcher is not used Via DM Switcher TCP IP Communication via DM Switcher To establish TCP IP...

Page 33: ...lbox to create an entry using the expected communication protocol USB When multiple USB devices are connected identify the DM switcher by entering DM MD8X8 DM MD16X16 or DM MD32X32 in the Model textbox the unit s serial number in the Serial textbox or the unit s hostname in the Hostname textbox The hostname can be found in the System Info window in the section marked Ethernet however communication...

Page 34: ...y holding down its SETUP button while applying power This IP address overwrites any previous settings and remains until it is changed manually 2 Use the Address Book in Crestron Toolbox to create an entry for the DM receiver using the TCP connection type and enter the IP address of the DM receiver 3 Display the System Info window of the DM receiver click the icon communications are confirmed when ...

Page 35: ...onnected to a switcher or the DM receiver if the DM receiver is used in a standalone configuration and then click OK Either of the following occurs If the DM switcher was selected a DM device list is displayed that allows an upgrade to DM devices connected to the switcher If the DM receiver was selected a DM device list is displayed that allows an upgrade to the DM receiver only In the DM device l...

Page 36: ...port Verify cable connection to the DM IN port Device is not receiving video signal Ensure proper video signal is routed to device VIDEO LED does not illuminate Device connected to the HDMI OUT port has not sent the hotplug signal Power on device connected to the HDMI OUT port and ensure that it is switched to the correct input VIDEO LED is green but video on connected display is black HDCP is bla...

Page 37: ...in Crestron Toolbox Reference Documents The latest version of all documents mentioned within the guide can be obtained from the Crestron Web site List of Related Reference Documents DOCUMENT TITLE Crestron DigitalMedia Design Guide www crestron com dmresources Crestron DigitalMedia Switchers Operations Guide www crestron com manuals Crestron e Control Reference Guide www crestron com manuals Crest...

Page 38: ...made available as manual updates These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision Check the Crestron Web site periodically for manual update availability and its relevance Updates are identified as an Addendum in the Download column 32 DigitalMedia 8G Fiber Receiver 200 DM RMC 200 S S2 Operations Installat...

Page 39: ...t heads and power supplies are covered for a period of one 1 year touch screen display and overlay components are covered for 90 days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from Crestron or an authorized Crestron dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any Crestron shal...

Page 40: ...derstands that there is no warranty for this free software If the software is modified by someone else and passed on we want its recipients to know that what they have is not the original so that any problems introduced by others will not reflect on the original authors reputations Finally any free program is threatened constantly by software patents We wish to avoid the danger that redistributors...

Page 41: ...ogram or a work based on it under Section 2 in object code or executable form under the terms of Sections 1 and 2 above provided that you also do one of the following a Accompany it with the complete corresponding machine readable source code which must be distributed under the terms of Sections 1 and 2 above on a medium customarily used for software interchange or b Accompany it with a written of...

Page 42: ...s restricted in certain countries either by patents or by copyrighted interfaces the original copyright holder who places the Program under this License may add an explicit geographical distribution limitation excluding those countries so that distribution is permitted only in or among countries not thus excluded In such case this License incorporates the limitation as if written in the body of th...

Page 43: ...Crestron DM RMC 200 S S2 DigitalMedia 8G Fiber Receiver 200 This page is intentionally left blank Operations Installation Guide DOC 7246B DigitalMedia 8G Fiber Receiver 200 DM RMC 200 S S2 37 ...

Page 44: ...ron Electronics Inc Operations Installation Guide DOC 7246B 15 Volvo Drive Rockleigh NJ 07647 2031698 Tel 888 CRESTRON 10 12 Fax 201 767 7576 Specifications subject to www crestron com change without notice ...