30 • DM Lite® 4K60 4:4:4 Extenders
Product Manual — Doc. 9259A
Wall Plate Transmitter Power Connection
No power pack is included with a wall plate DM Lite transmitter. Be aware of the following:
l
When a wall plate DM Lite transmitter is paired with a surface-mountable DM Lite
receiver, the power pack included with the receiver is used to power both devices. Power is
transmitted over the CATx cable that connects the wall plate transmitter to the surface-
mountable receiver.
l
When a wall plate DM Lite transmitter is paired with a DMPS Lite switcher, the switcher
provides power to the transmitter. Power is transmitted over the CATx cable that
connects the wall plate transmitter to the switcher.
l
If a wall plate DM Lite transmitter is paired with a wall plate DM Lite receiver, the devices
must be powered independently by a PW-2407WUL power pack (sold separately) for each
device. A wall plate transmitter and wall plate receiver cannot provide power over the
CATx cable to the remote device with which it is paired.
Wall Plate Receiver Power Connection
No power pack is included with a wall plate DM Lite receiver. Be aware of the following:
l
When a wall plate DM Lite receiver is paired with a surface-mountable DM Lite
transmitter, the power pack included with the transmitter is used to power both devices.
Power is transmitted over the CATx cable that connects the wall plate receiver to the
surface-mountable transmitter.
l
When a wall plate DM Lite receiver is paired with a DMPS Lite switcher, the switcher
provides power to the receiver. Power is transmitted over the CATx cable that connects
the wall plate receiver to the switcher.
l
If a wall plate DM Lite receiver is paired with a wall plate DM Lite transmitter, the devices
must be powered independently by a PW-2407WUL power pack (sold separately) for each
device. A wall plate receiver and wall plate transmitter cannot provide power over the
CATx cable to the remote device with which it is paired.