Crestron
DA-1700CW
Docking Assembly for STX-1700CW/CXPW
C2Net-Device Slot in Configuration Manager
The C2Net-Device Slot can accept a DA-1700CW. Once a DA-1700CW is
configured in a C2Net-Device Slot, the slot allows Cresnet communication between
the DA-1700CW and the control system.
NOTE
: Refer to the appropriate touchpanel manual for information on developing a
program that includes a touchpanel to be docked in the docking station.
In Configuration Manager, drag the BB/DA-1700CW from the Cresnet Control
Modules | Cresnet I/O Control & Other Modules folder of the
Device Library
and
drop it on the PRO2 C2Net-Device slot in
System Views
. The
System Views
upper
pane displays the BB/DA-1700CW device icon below the PRO2 graphic. The PRO2
system tree displays the BB/DA-1700CW in Slot 9, with a default Net ID of 51.
Refer to the graphic below.
C2Net Device, Slot 9
Setting the Net ID in Device Settings
Double-click the BB/DA-1700CW icon in the upper pane to open the “Device
Settings” window (shown below). This window displays BB/DA-1700CW device
information. The Net ID can be changed in this window using the
Net ID
tab.
“Device Settings” Window
NOTE
: SIMPL Windows automatically changes Net ID values of a device added to
a program if a duplicate device or a device with the same default Net ID already
Operations and Installation Guide - DOC. 6104A