Docking Assembly for STX-1700CW/CXPW
Crestron
DA-1700CW
Wire Gauge Values
RESISTANCE (R)
WIRE GAUGE
4
16
6
18
10
20
15
22
13
Doubled CAT5
8.7
Tripled CAT5
NOTE:
All Cresnet wiring must consist of two twisted-pairs. One twisted pair is the
+24V conductor and the GND conductor and the other twisted pair is the Y
conductor and the Z conductor.
NOTE:
When daisy-chaining Cresnet units, strip the ends of the wires carefully to
avoid nicking the conductors. Twist together the ends of the wires that share a pin on
the network connector, and tin the twisted connection. Apply solder only to the ends
of the twisted wires. Avoid tinning too far up the wires or the end becomes brittle.
Insert the tinned connection into the Cresnet connector plug and tighten the retaining
screw. Repeat the procedure for the other three conductors.
Identity Code
Every equipment and user interface within the network requires a unique identity
code (Net ID). These codes are two-digit hexadecimal numbers from 03 to FE. The
Net ID of each unit must match an ID code specified in the SIMPL Windows
program. Refer to “Setting the Net ID in Device Settings” on page 11 for details of
the SIMPL Windows procedure.
The Net ID of the DA-1700CW is factory set to
51
. The Net IDs of multiple
DA-1700CWs in the same system must be unique and changed from a personal
computer (PC) via Crestron Viewport.
NOTE:
For detailed information on establishing communication between the PC
and the Control System, refer to the latest version of the 2-Series Control System
Reference Guide (Doc. 6256) or the respective Operations Guide for the control
system.
Complete the following steps to change the Net ID.
1. Ensure that the DA-1700CW is the only device connected to the control
system.
2. Open the Crestron Viewport.
3. From the Viewport menu, select
Functions | Set Network ID
. The
software checks the baud rate and then opens the "Set Network ID"
window.
4. In the “Set Network ID” window, select the DA-1700CW from the
Current Network Devices
text window.
5. From
the
Choose the new network ID for the selected device (Hex):
text
box, select the new Net ID for the DA-1700CW.
6
•
Docking Assembly for STX-1700CW/CXPW: DA-1700CW
Operations and Installation Guide - DOC. 6104A