![Crestron CSA-DECOR5-BRKT Series Quick Start Manual Download Page 8](http://html1.mh-extra.com/html/crestron/csa-decor5-brkt-series/csa-decor5-brkt-series_quick-start-manual_2685277008.webp)
4. Use the spanner wrench to raise the fabric until it is level with the
adjacent fabric.
Raise the Fabric until it is Level with the Adjacent Fabric
5. Hold the band that is being leveled stationary with one hand while
rotating the locking collar in the direction of lowering the shade until
the collar comes to a hard stop. This is necessary to securely lock the
shade in place.
6. Run the shades through three full close and open cycles to allow the
fabric to settle on the tube.
7. Verify that the fabric is level. If it is not, repeat steps 1 and 2 until the
fabric is level.
Adjust the Roller Shade Assembly
Once the roller shade assembly is mounted, make adjustments to level the
shade and center it in the opening.
WARNINGS:
l
Care has been taken to make sure that the shade is properly
balanced. Prior to initial operation, please confirm that the brackets
have been adjusted so that the shade hangs level and plumb. Upon
startup, run the shade all the way down and check for plumb.
Observe the shade closely as it rolls up. If the shade begins to
telescope, stop immediately and take the appropriate action to make
sure that the shade tracks properly. To prevent damage to the fabric
from telescoping, do not leave the shade unattended during the first
few cycles of operation. Failure to follow these instructions may
result in damage to the edge of the fabric, which is not covered by the
warranty.
l
If the roll-up diameter is close to the maximum allowance, do not use
the vertical adjustment screw to level the shade. The fabric may
come in contact with the bracket, fascia, or other hardware, which
may cause damage to the fabric. Remount the bracket to level the
shade.
Situations that may cause telescoping:
l
The shade is not perfectly level.
l
The shade may bump into objects while traveling up or down.
l
The HVAC ductwork is blowing on the shade, or air is coming in
through a window.
l
A foreign object is stuck to the shade fabric (for example tape, bugs,
dust, etc.).
Ways to prevent telescoping:
l
Use the leveling features built into the shade brackets to make sure the
shade is level. If the bracket adjustment is not enough to compensate,
use a shim to level the system.
8
CSA-DECOR5 Series
Quick Start
Shade Motor Bracket Installation and Motor Programming