To check the communications status of the device, tap the SET button
three times and then press and hold it down (tap-tap-tap-press+hold) for
up to 2 seconds. The LED flashes to indicate the communications status.
Refer to the following table for details.

LED

Communications Status

Turns on for 5
seconds

The device is communicating with the control system.

Flashes twice

The device was previously joined to the network but is not
communicating with the gateway.

Flashes once

The device is not joined to the network.

LED Diagnostics

The LED flashes to provide a visual reference that the motor is operating
normally or if it is in an error state.

Normal Operation

The following table provides a list of possible LED patterns encountered
during normal operation. All LEDs extinguish after 1 minute of inactivity if
there are no errors to report.

LED Patterns

LED Pattern

LED

Color

Operating Mode

Two fast flashes, then pause
(1/8-second on, 1/8-second off,
1/8-second on, 5/8-second off)

Blue

A firmware upgrade over
the Cresnet® network is
in progress.

Slow flash (1/2-second on, 1/2-second
off)

Blue

The motor’s internal
firmware upgrade is in
progress.

Solid

Blue

The motor is in
Bootloader mode.

Fast flash (1/4-second on, 1/4-second
off)

White

The motor is in
Identify mode.

Slow flash (1/2-second on, 1/2-second
off)

Green

The motor is moving
from a local button
press.

Solid

Green

The motor is
communicating with the
control system program.

Slow flash (1/2-second on, 1/2-second
off)

Red

The motor is not
communicating with the
control system.

15

CSA-DECOR5 Series

Quick Start

Shade Motor Bracket Installation and Motor Programming

Summary of Contents for CSA-DECOR5-BRKT Series

Page 1: ...masonry installations It is the responsibility of the installer to make sure that the mounting method used is secure l Ensure that all mounting brackets are level and on the same plane l All shades m...

Page 2: ...right side of the window opening l The motor bracket mounts on the left side of the window opening NOTES l The stamped L and R should face the wall and window l For inside mounts secure the mounting...

Page 3: ...acket exactly centered on the band to band dimension that is indicated on the order form and secure it using the supplied mounting screws Outside Mount Inside Mount 3 CSA DECOR5 Series Quick Start Sha...

Page 4: ...NOTES l The latch must be oriented so that the release levers are pointing in the same direction as the buttons l When mounted to the motor the raised side of the latch faces the window jamb l The lat...

Page 5: ...There is a motor band an idler band and optionally one or more intermediate bands l The motor band has a retractable pin on one side and the motor on the other l The intermediate band has a retractabl...

Page 6: ...is being installed into a coupler insert the half extended retractable pin into the next coupler l If the next band is being installed into an idler bracket insert the idler band s idler pin into the...

Page 7: ...veling must be performed with the bottom of the shade fabric at eye level 1 Hold the drive band stationary 2 Use the spanner wrench on the idler band or the first intermediate band next to the motor b...

Page 8: ...e shade begins to telescope stop immediately and take the appropriate action to make sure that the shade tracks properly To prevent damage to the fabric from telescoping do not leave the shade unatten...

Page 9: ...r into Limit Setup mode l If the fabric is telescoping to the left place the tape on the right side of the tube l If the fabric is telescoping to the right place the tape on the left side of the tube...

Page 10: ...eft hand bracket so that the keyhole is parallel to the wall when the bracket is mounted Make sure that the screw head on the vertical adjustment screw faces down 3 Secure the idler mount with the scr...

Page 11: ...the Cables To ensure proper functionality and a clean look consider the following when routing cables and making connections l The cables should exit the wall near the motor end of the shade assembly...

Page 12: ...erformed remotely using a control system The timeout and LED indicators are the same as described in this document Controls and Indicators The Crestron CSM I QMTDC shade motors have UP SET and DN down...

Page 13: ...the shade hangs level and plumb Upon startup run the shade all the way down and check for plumb Observe the shade closely as it rolls up If the shade begins to telescope stop immediately and take the...

Page 14: ...upper limit was successfully set Joining an infiNET EX Network infiNET EX Interfaces Only The device connects to the Crestron network via the infiNET EX communications protocol Use the procedures out...

Page 15: ...s to provide a visual reference that the motor is operating normally or if it is in an error state Normal Operation The following table provides a list of possible LED patterns encountered during norm...

Page 16: ...The motor is not being polled by the control system Ensure that the Net ID matches the control system program and that the program is running on the control system Troubleshooting The following table...

Page 17: ...crestron com warranty The specific patents that cover Crestron products are listed at www crestron com legal patents Certain Crestron products contain open source software For specific information vis...

Reviews: