Crestron
CNX-PVID8x4
Professional Video Distribution Switch
Operations Guide - DOC. 8166A
Professional Video Distribution Switch: CNX-PVID8x4
•
3
source must connect to a specific group of input connectors, which is dependent on
the hardware configuration chosen. Refer to "Hardware Configurations" on page 14
for specific connection details.
CNX-PVID8x4 used without Crestron Room Solution Box
In this system, the CNX-PVID8x4 has an incredible amount of flexibility with
respect to making connections to all three types of video sources. For example, it is
possible to have a composite source connected to INPUT 1, level 1 and an S-video
source connected to INPUT 1, levels 2 and 3, simultaneously. However, the Crestron
AppBuilder cannot be used for the programming portion of this kind of system. All
programming is done entirely in SIMPL Windows.
Specifications
The following table provides a summary of specifications for the CNX-PVID8x4.
Specifications of the CNX-PVID8x4
SPECIFICATION DETAILS
Power Requirements
40 Watts (1.67 Amp @ 24 VDC)
Default Net ID
41
Control System Update Files
1, 2, 3
2-Series Control System
CNMSX-AV/PRO
CNRACKX/-DP
CEN/CN-TVAV
ST-CP
Version 2.004.CUZ or later
Version 5.14.02X.UPZ or later
Version 5.14.02W.UPZ or later
Version 5.12.63V.UPZ or later
Version 4.02.4S.UPZ or later
CNX-PVID8x4 Firmware
4
PVID_16.upg or later
PVID_16.s19 or later
Rack space required
4U high; 1U wide
Video bandwidth
100 MHz
Crosstalk
> -60 dB
Environmental temperature range
41° to 104°F (5° to 40°C)
Humidity
10% to 90% RH (non-condensing)
Dimensions
(without mounting ears)
Height: 6.97 in (17.70 cm)
Width:
17.29 in (43.92 cm)
Depth:
8.45 in (21.46 cm)
Weight
9.81 lb (4.45 kg)
1
The latest versions can be obtained from the Downloads | Software Updates section of the Crestron
website (
. Refer to following NOTE.
2
Crestron 2-Series control systems include the AV2 and PRO2. Consult the latest Crestron Product
Catalog for a complete list of 2-Series control systems.
3
Filenames for CNX and ST-CP update files have a UPZ extension. Files on the website may be .zip
or self-extracting .exe files containing the .cuz or .upz file. All can be obtained from the Downloads
section of the Crestron website. To avoid program problems, make sure you are using the update file
with the correct suffix letter (e.g., S, V, W, X)
4
Refer to firmware upgrade release notes for applicability.
NOTE
: Crestron software and any files on the website are for Authorized Crestron
dealers and Crestron Authorized Independent Programmers (CAIP) only. New users
may be required to register to obtain access to certain areas of the site (including the
FTP site).