Crestron CLW-SLVS User Manual Download Page 1

 

CLW-SW, SWS, & SLVS(W/A/B)

 

CLW-SW, CLW-SWS, & CLS-SLVS Specifications 
(continued) 

Introduction 

SPECIFICATION DETAILS 

Load Ratings

3

 

 

Incandescent / Tungsten 
Halogen 

-SW: 1000W 
-SWS: 1000W 
-SLVS: N/A 

Magnetic Low Voltage

4

 -SW: 

1000VA/750W 

-SWS: 1000VA/750W 
-SLVS: N/A 

Neon / Cold Cathode

4

 -SW: 

1000VA/750W 

-SWS: 1000VA/750W 

-SLVS: N/A 

Electronic Low Voltage 

-SW: 1000W 
-SWS: 1000W 
-SLVS: N/A 

Fluorescent / 
High Intensity Discharge 
(HID) 

-SW: 8A 
-SWS: 8A 
-SLVS: N/A 

General Purpose Fan 

-SW: 3.0A 
-SWS: 3.0A 
-SLVS: N/A 

Minimum Load 

40W / 0.5A 

Operating Temperature 
and Humidity 

32°F to 104°F (0°C to 40°C ) 
10 to 90% Relative Humidity 
(Non-Condensing) 

Dimensions and Weight 

-SW and -SWS: 
  Height: 4.13 in (10.48 cm) 
  Width: 2.38 in (6.03 cm) 
  Depth: 1.91 in (4.85 cm) 
  Weight: 4.4 oz (0.61 kg) 
-SLVS: 
  Height: 4.13 in (10.48 cm) 
  Width: 1.75 in (4.45 cm) 
  Depth: 1.91 in (4.85 cm) 
  Weight: 3.6 oz (0.50 kg) 

Features and Functions 

The CLW-SW (-SW) is a stand-alone wall box switch 
that can also act as a Cresnet

®

 device that reports to a 

Crestron

®

 control processor. The -SW includes two 

isolated, non-polarized Cresnet wires (plus a ground wire) 
for connecting to a Cresnet system over a twisted pair 
wire with shield.  

The CLW-SW features a three-position mode selection 
switch. Refer to “Operating Buttons and Switches ” on 
page 5 for more information. In the absence of Cresnet 
communications, the switch can still be used to control a 
load. 

The CLW-SWS (-SWS) is similar to the -SW with the 
added capability of working with a slave unit  
(CLW-SLVS) in a multi-switch / single circuit 
application. 

The CLW-SLVS (-SLVS) is a slave unit that when used 
in conjunction with the -SWS acts as an additional switch 
control point in a multi-switch / single circuit application. 
It does not connect to a Cresnet system and cannot be 
used without a -SWS. The -SLVS does not have a mode 
selection switch and is not programmable. It emulates the 
operation of the -SWS to which it is connected. 

The -SW, -SWS, and -SLVS are available in white, 
almond, and black. White units are designated by part 
numbers ending in “W”. Almond units are designated by 
part numbers ending in “A”. Black units are designated by 
part numbers ending in “B”. These switches can be 
covered with a decorative faceplate (not supplied). 

Specifications 

1. 

The latest software versions can be obtained from the Crestron 
website. Refer to the NOTE following these footnotes. 

Following are specifications for the -SW, -SWS, and  
-SLVS. 

2. 

Crestron 2-Series control systems include the AV2 and PRO2. 
Consult the latest Crestron Product Catalog for a complete list of 
2-Series control systems. 

CLW-SW, CLW-SWS, & CLS-SLVS Specifications 

SPECIFICATION DETAILS 

Power Requirements 

Line Power, 120 VAC, 60 Hz 

Default Net ID 

SW: 6F 
SWS: 70 

Switch Type 

Single-Pole, Single-Throw 

Load Type 

Incandescent, Tungsten Halogen, 
Fluorescent / High Intensity 
Discharge (HID), Electronic Low 
Voltage, Magnetic Low Voltage, Neon 
/ Cold Cathode, General Purpose Fan 

2-Series Control System 
Update File

1,2

 

Version 3.093 or later 

3. 

Refer to Derating Charts for Multigang Installations on page 3. 

4. 

VA ratings are for input power to the transformer. If you do not 
know the input power requirement of the transformer, use the 
bulb’s wattage rating to determine proper rating. 

NOTE:

  Crestron software and any files on the website 

are for Authorized Crestron dealers and Crestron 
Authorized Independent Programmers (CAIP) only. New 
users may be required to register to obtain access to 
certain areas of the site (including the FTP site). 

Crestron Electronics, Inc.

 

Installation Guide – DOC. 6134B

 

15 Volvo Drive   Rockleigh, NJ 07647

 

(2008088)

   

Tel: 888.CRESTRON

 

06.05

   

Fax: 201.767.7576

  

Specifications subject to 

 

www.crestron.com

 

change without notice.

 

(continued on next column) 

Reviews: