Crestron CLW-SLVS User Manual Download Page 4

CLW-SW, SWS, & SLVS(W/A/B)

 

 

section breaks off from the mounting plate. Use a 
file or sandpaper to remove any excess metal. 

NOTE:

  New installations should be checked for short 

circuits prior to installing the -SW, -SWS, or -SLVS. 
With power off, close the circuit and restore power. If the 
load does not work or a breaker trips, check and correct 
the wiring or fixture (if necessary). Install the -SW,  
-SWS, or -SLVS only when the short is no longer present. 

The warranty is void if the -SW, -SWS, or -SLVS is 
installed and operated with a shorted load

Prewire for Master Application 

Each device has two Class 2 low voltage wires (plus a 
ground wire) that provide a Cresnet connection over 
shielded twisted-pair to a Crestron control system. These 
wires are routed to the bottom of the device for 
connection outside of the wallbox. The low voltage wires 
are pulled from each device location to the control 
system, a Crestron power supply, a Crestron C2N-NPA8 
Poll Accelerator, or a Crestron connection block device. 
Use # 22 AWG, twisted, shielded, 2-conductor wire. 
Wiring can be daisy chained, T-tapped, or home run back 
to the control system. Refer to the following wiring 
diagram. 

1.  Turn power off at the circuit breaker. 

2.  If installing multiple switches (-SW or -SWS), 

note the serial number on each device and make 
sure they are being installed in the proper 
location. 

3.  Pull Class 2 low voltage wires through a hole in 

the drywall located outside of the electrical box, 
to the Crestron control system, a Crestron power 
supply, a Crestron C2N-NPA8, or a Crestron 
connection block device. Leave wires outside of 
the wallbox for connection to the -SW or -SWS. 

Wiring Diagram of CLW device to Cresnet 

 

NOTE:

  Alternate wiring methods may be used for the 

Class 2 wiring connections. Refer to section 725-55, Part 
D of the 2002 National Electric Code. 

4.  Wire the device for the appropriate application. 

Choose either “CLW-SW / CLW-SWS Wiring” 
or “CLW-SWS with CLW-SLVS Wiring”
shown on this page and the following page. 

NOTE:

  The GRAY (Cresnet) wires are not polarized. 

These wires can be connected to either the Y or Z line on 
a Cresnet port. 

CLW-SW / CLW-SWS Wiring 

NOTE:

  The -SW and -SWS require a neutral wire for 

operation. If no neutral is present, contact a licensed 
electrician for installation. 

NOTE:

  The BLACK wire (Cresnet ground) should not 

be grounded with the GREEN (Ground) wire on the  
-SW/-SWS/-SLVS. 

The following wiring diagram illustrates installation of 
the -SW or -SWS. 

NOTE:

  Crestron recommends using Crestron’s 

Cresnet-

DM

 cable for connecting the -DIM and -DIMS to the 

Cresnet network. 

Wiring Diagram for CLW-SW or CLW-SWS (without CLW-
SLVS) 

Hot

Neutral

Load

RED

BLACK

BLUE

Ground

GREEN

LINE

120VAC

60Hz

(-SWS ONLY)

WHITE

Cresnet

 

Installation 

NOTE:

  The -SWS must be installed in the same wallbox 

that contains the connections to the load. 

NOTE:

  The -SW, -SWS require a neutral wire for 

operation. If no neutral is present, contact a licensed 
electrician for installation. 

WARNING:

  Turn off power at the circuit breaker. 

Installing with power on can result in serious personal 
injury and damage to the device. 

4  

  Stand Alone Wall Box Switch :  CLW-SW, SWS, & SLVS 

Installation Guide – DOC. 6134B 