Wideband RGB Matrix Switcher
Crestron
CEN-RGBHV
Hardware Hookup
Connect the Device
Make the necessary connections as called out in the illustration that follows this
paragraph. Refer to “Network Wiring” on page 17 before attaching the 4-position
terminal block connector. Apply power after all connections have been made.
Hardware Connections for the CEN-RGBHV (CEN-RGBHV12X8 Shown)
(VIDEO) IN:
FROM RGBHV OUTPUTS
(VIDEO) OUT:
TO RGBHV INPUTS
(AUDIO) IN:
FROM BALANCED/
UNBALANCED STEREO
LINE LEVEL OUTPUTS
(AUDIO) OUT:
TO BALANCED/
UNBALANCED STEREO
LINE LEVEL INPUTS
COMPUTER:
TO PC
VIDEO REF IN:
FROM SYNC REFERENCE
CRESNET:
TO CONTROL SYSTEM AND
OTHER CRESNET DEVICES
LAN:
10/100 BASE-T
ETHERNET TO LAN
100-240V ~2.0A
50/60 HZ:
MAIN POWER INPUT
GROUND
NOTE:
Ensure the unit is properly grounded.
Fuse Replacement
If the CEN-RGBHV does not power up when it is plugged into an AC outlet, one or
both fuses may need to be replaced. The fuse holder is located on the rear panel, as
the lower section of the IEC socket assembly. To replace one or both fuses:
1. Disconnect power to the CEN-RGBHV.
2. To release the fuse holder, grip the fuse holder top and bottom, while
pressing down on the tab in the center of the top.
3. Remove the defective fuse(s) from the fuse holder and replace with one or
two new ones as needed.
CAUTION:
Use only time lag type fuses, 2.5 Amps / 250 Volts for the line
(“hot”) leg and 10 Amps / 250 Volts for neutral leg. Failure to do so may cause
damage to the CEN-RGBHV.
20
•
Wideband RGB Matrix Switcher: CEN-RGBHV
Operations Guide – DOC. 6612C