2. Place the device into Acquire mode.
a. Tap the top button three times, and then press and hold it down
(tap-tap-tap-press+hold) until the top LED on the device flashes
once (this can take up to 10 seconds if the device has been
previously acquired to a gateway).
b. Release the button to start the acquire process. The top button's
LED flashes slowly to show that the device is actively scanning the
infiNET EX network.
l
The top button's LED turns on for 5 seconds to show that the
device has been successfully acquired to the infiNET EX network.
l
The top button's LED flashes quickly to indicate that the device
was not successfully acquired by the infiNET EX network. Tap
the top button to acknowledge failure to acquire the infiNET EX
network. Before attempting the acquire process again, ensure
one of the following:
o
The gateway is in Acquire mode and within range.
o
A non-battery powered infiNET EX device is in Acquire mode
on the same gateway.
3. Once all devices have been acquired, take the gateway out of Acquire
mode. Refer to the gateway’s manual for details.
Leaving an infiNET EX Network
To leave an infiNET EX network, put the device into Acquire mode, as
described in
, when no gateway is in
Acquire mode.
Verifying Communications Status
To check the communications status of the device, tap the top button
three times and then press and hold it down (tap-tap-tap-press+hold) for
up to 2 seconds. The top button's LED flashes to indicate the
communications status. Refer to the following table for details.
LED
Communications Status
Turns on
for 5
seconds
The device is communicating with the control system.
Flashes
three times
The device is communicating with the gateway, but the
gateway is not communicating with the control system.
Flashes
twice
The device was previously joined to the network but is not
communicating with the gateway.
Flashes
once
The device is not joined to the network.
Troubleshooting
The device displays error codes using the device LEDs. All LEDs flash a
pattern to indicate the error on that output. For example, a 1-2 error
flashes all LEDs one time, pauses for 1 second, flashes two times, pauses
for 2 seconds, and then repeats for 90 seconds (except where otherwise
noted). Refer to the following table for possible corrections.
Error
Code
Fault Name
Fault Description
2-1
Over
Current
A short circuit has been detected. Verify that there
are no shorts in the wiring and that the total load
output matches the proper ganged ratings.
2-2
Shorted FET
A flowing current is detected when an FET should be
off. The load will power to 100%. This error code is
permanent until the device is power cycled.
Disconnect the load and contact Crestron Technical
Support.
2-3
Over
Temperature
The dimmer has overheated and shut down due to an
excessive load. Verify that the total load matches the
proper ganged rating. The dimmer resumes normal
operation after cooling.
10
CLW-DIMUEX-P
Quick Start
Cameo® In-Wall Universal Phase Dimmer, 120 VAC