Switches: Mechanical 3- or 4-way switches do not work with
CLW-DIMUEX-P dimmers.
l
Spacing: If mounting one device above another, leave at least 4 1/2 in.
(115 mm) vertical space between them.
l
Low Voltage Applications: Operation of a low voltage circuit with all
lamps inoperative or removed may result in current flow in excess of
normal levels. To avoid transformer overheating and premature
transformer failure, Crestron recommends the following:
o
Do not operate low voltage circuits without operative lamps in
place.
o
Replace burned-out lamps as quickly as possible.
o
Use transformers that incorporate thermal protection or fuse
transformer primary windings to prevent transformer failure due
to overcurrent.
Installation
Install the CLW-DIMUEX-P:
1. Turn power off at the circuit breaker.
2. Wire the device as shown in the following diagrams.
NOTES:
l
The dimmer and any connected remote dimmer
(CLW-SLVU-P) requires a neutral wire connection.
l
Up to four CLW-SLVU-P remote dimmers can be used with a
CLW-DIMUEX-P dimmer. To wire one or more CLW-SLVU-P
remote dimmers, refer to the
(Doc. 7364).
3. Fold the wires into the electrical box. Avoid pinched wires.
4. Fasten the device to the electrical box with the provided screws.
5. Attach the FP-G1 faceplate (not supplied).
6. Ensure all buttons, including the program button and air-gap switch,
actuate without sticking.
7. Restore power at the circuit breaker.
2
CLW-DIMUEX-P
Quick Start
Cameo® In-Wall Universal Phase Dimmer, 120 VAC