background image

Crestron 

C2N-CAMIDSPT

   

Camera Interface, Digital Servo Pan Tilt Head

 

 

Operations Guide - DOC. 6262A 

Camera Interface, Digital Servo Pan Tilt Head: C2N-CAMIDSPT  

  25 

CAMIDSPT General Controls Input and Output Signal Descriptions (continued) 

SIGNAL TYPE 

AND NAME 

DESCRIPTION 

Digital input: 
<

Iris_Local/Auto_Mode

Selects manual or auto mode for controlling the iris. When low 
(default), selects auto mode. When high, selects manual mode.  
High/1 = Manual mode. Low/0 (default) = Auto mode. 

Analog input: <

Preset#

Selects the internal preset to be saved (on the rising edge of 
<

SetPreset

>) or recalled (on the rising edge of 

<

RecallPreset

>). 

Valid values range from 1 to 100. Out of range values are 
disregarded. 

Analog input: 
<

PT_Spd/Time

Specifies either the speed or time, as determined by the 
<

PT_Spd/Time_Adj

> input, for setting the pan/tilt unit to a 

specified position and for recalling presets. 
When in Speed mode, sets the speed for traveling from the 
current pan/tilt position to the target position. The speed ranges 
from 0% (minimum speed) to 100% (maximum speed). 
When in Time mode, sets the time for traveling from the current 
position to the target position. Valid values range from 0.1s to 
25.5s, adjustable in 0.01s increments. 

Analog input: 
<

PT_Acceleration

Sets the acceleration and deceleration for the pan/tilt axes from 
a range of 1% (minimum acceleration) to 100% (maximum 
acceleration). A value of 0% will set the acceleration to a 
default state. 

Analog input: 
<

LensTransTime

Sets the zoom, focus, and iris transition time when the 
ZoomPos, FocusPos, or IrisPos analog input joins are driven. 
This is applicable to servomotor lenses in position mode. 
Valid values range from 0.1s to 25.5s and are adjustable in 
0.01s increments. 

Analog input: <

PanPos

Sets the absolute pan position at the speed or time given by 
the <

PT_Spd/Time

> analog. 

Valid values range from 1 to 65535. A value of 0 will cause no 
movement. A command to a specific position will be processed 
as a preset recall. 

Analog input: <

TiltPos

Sets the absolute tilt position at the speed or time given by the 
<

PT_Spd/Time

> analog. 

Valid values range from 1 to 65535. A value of 0 will cause no 
movement. A command to a specific position will be processed 
as a preset recall. 

Analog input: <

ZoomPos

Sets the absolute zoom position for motorized lenses with 
potentiometer feedback and servomotor lenses in position 
mode. The zoom position is adjusted in the time given by the 
<

LensTransTime

> analog. 

Valid values range from 1 to 65535. A value of 0 will cause no 
movement. A command to a specific position will be processed 
as a preset recall. 

Analog input: 
<

FocusPos

Sets the absolute focus position for motorized lenses with 
potentiometer feedback and servomotor lenses in position 
mode. The focus position is adjusted in the time given by the 
<LensTransTime> analog. 
Valid values range from 1 to 65535. A value of 0 will cause no 
movement. A command to a specific position will be processed 
as a preset recall. 

Analog input: <

IrisPos

Sets the absolute aperture position for servomotor lenses only.  
The aperture is adjusted in the time given by the 
<

LensTransTime

> analog. 

Valid values range from 1 to 65535. A value of 0 will cause no 
movement. A command to a specific position will be processed 
as a preset recall. 

(continued on next page) 

Summary of Contents for C2N-CAMIDSPT

Page 1: ...Crestron C2N CAMIDSPT Camera Interface Digital Servo Pan Tilt Head Operations Guide...

Page 2: ...by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respectiv...

Page 3: ...Code 12 Camera Lens Mounting 14 Hardware Hookup 17 Power Up Conditions 18 Limit Stop Adjustment 18 Calibration 19 Programming Software 20 Earliest Version Software Requirements for the PC 20 Programm...

Page 4: ......

Page 5: ...both pan and tilt axes can be set to limit extreme movement thus preventing potential damage to the camera and lens Initial setup is made easy using the built in 5 way mini joystick to provide local...

Page 6: ...For these lenses the IRIS_LOCAL AUTO_MODE digital input join should be set to AUTO The CAMIDSPT supports motorized lenses with potentiometer feedback for the zoom and focus lens functions With potent...

Page 7: ...controller based recalls Personality Modules Plug in personality modules define the lens configuration with modules available for 6 8 and 12 V motorized lenses as well as 2 5V to 7 5V servomotor lense...

Page 8: ...at unit Unlimited stored in Cresnet network controller Maximum Camera Lens Load 15 lbs 6 80 kg properly balanced Pan Tilt Position Control Optical encoder Pan and Tilt Limit Stops Adjustable hard stop...

Page 9: ...n hub and one on the rear tilt hub for pan and tilt axis motion Hard stops located on the unit and two adjustable locking screws on each disk limit rotation in each axis to prevent damage to the mount...

Page 10: ...y Refer to the following table for exact voltage outputs for each personality module NOTE If no personality module is connected the lens outputs are disabled Personality Module Options MODULE VOLTAGE...

Page 11: ...for connection to the control system LENS This DB15 female connector provides three channels for zoom focus and iris as well as additional signals depending on the lens Refer to the diagram and pinou...

Page 12: ...US SPEED POS SERVO 2 5V POT 3 3V M n c Zoom Feedback Focus Feedback Zoom Motor Focus Motor Iris Motor M M n c Wiring Diagram for Lens C KTS KTS A Series and MD BMD SD Series IRIS SPEED POS POT GND ZOO...

Page 13: ...communication between the control system and the CAMIDSPT is established Illumination indicates that the SIMPL program currently loaded has a network device defined at the same NET ID as the CAMIDSPT...

Page 14: ...oystick operation During this time communications with the Cresnet network are not active Before powering down the unit should be allowed to exit local mode operation The green LED will blink at a slo...

Page 15: ...nfiguration available from the Crestron website When calculating the wire gauge for a particular Cresnet run the length of the run and the Cresnet power usage of each network unit to be connected must...

Page 16: ...er to the Troubleshooting Communications section in the respective Operations Guide for the control system There are two different methods Method A or Method B for setting the CAMIDSPT Net IDs Method...

Page 17: ...g this method you should have a list of all current network devices and their Net IDs to avoid assigning duplicate IDs Set Net ID by TSID These procedures are for TSID enabled network devices during t...

Page 18: ...work you need to locate a particular one you know the TSID but not the serial number and your site installation list is based on device serial numbers In this or the reverse situation do the following...

Page 19: ...m Mark Centerline MOUNTING PLATE SUPPORT BRACKET TILT HUB Mark Centerline 0 75 in 1 91 cm 0 75 in 1 91 cm CAMERA ALIGNMENT PEG 2 Measure 1 5 inches 3 81 cm from the left edge of the mounting plate Use...

Page 20: ...Balance Centerline Mark Centerline Intersection MOUNTING PLATE 8 Disassemble the camera lens assembly from the support bracket and mark the intersection point of the optical centerline distance and t...

Page 21: ...hookup diagram below Other than making the power connection last complete the connections in any order NOTE To ensure safe operation of the CAMIDSPT all cables around the unit must be properly dressed...

Page 22: ...Up Conditions At power up the CAMIDSPT executes a short series of pan tilt movement while it calibrates its home position The unit must have unrestricted movement in a range of 30 degrees This homing...

Page 23: ...proper settings NOTE Hard stops should not be set any closer to the pan and tilt home positions than 30 degrees Hard stops set closer will prevent the unit from executing the power up homing routine...

Page 24: ...res SIMPL Cross Compiler version 1 1 Crestron Database version 16 1 0 or later Required by SIMPL Windows Programming with SIMPL Windows NOTE The following are acceptable file extensions for programs t...

Page 25: ...and configure the communications ports Expanded PRO2 System Tree C2Net Device Slot in Configuration Manager To incorporate a CAMIDSPT into the system drag the CAMIDSPT from the Cresnet Control Modules...

Page 26: ...hat the hardware and software settings of the Net ID match For Net ID hardware setting details refer to Identity Code on page 12 CAMIDSPT Symbol in Programming Manager Programming Manager is where pro...

Page 27: ...h potentiometer feedback and servo lenses in position mode Digital Input Recall Preset Recall an internal preset 1 100 from the pan tilt Preset number determined by same analog input join as above Ris...

Page 28: ...portPos request One half second pulse duration High 1 rising edge Data valid Low 0 no pulse Data not valid Digital input Iris_Spd Pos_Mode Selects position or speed mode for controlling the aperture i...

Page 29: ...Pos analog input joins are driven This is applicable to servomotor lenses in position mode Valid values range from 0 1s to 25 5s and are adjustable in 0 01s increments Analog input PanPos Sets the abs...

Page 30: ...where a value of 50 stops the tilt movement A value of 0 signifies the maximum reverse speed while a value of 100 signifies the maximum forward speed Analog input ZoomRate Zooms in or out in response...

Page 31: ...low the symbol is disabled str1 The C2N CAMIDSPT RS 232 port is capable of receiving complex serial data in the form of serial data strings on this input line str2 The C2N CAMIDSPT RS 232 port is capa...

Page 32: ...trol system and a PC It is used to observe system processes upload new operating systems and firmware change system and network parameters and communicate with network device consoles and touchpanels...

Page 33: ...s or VT Pro e and from the menu bar select Tools Viewport 2 Refer to the figure after this step From the Viewport menu select Setup Communications settings alternatively press Alt D to open the Port S...

Page 34: ...shooting Communications section in the respective Operations Guide for the control system Uploading a SIMPL Windows Program A control system source file has the extension smw A compiled SIMPL Windows...

Page 35: ...shown on the Send Program window Send Program Window 4 To verify that the program has been transferred successfully select Diagnostics Report Program Information This should display a window that prov...

Page 36: ...mware Command 3 As shown after this step select the Net ID of the CAMIDSPT and then click OK The Open window appears refer to the subsequent graphic Select Network ID Window NOTE When transferring any...

Page 37: ...s secure Unit does not function Hardstop or other obstruction prevents unit from executing power up homing functions Adjust hardstops or remove obstruction Unit reached a limit Verify that calibration...

Page 38: ...stron worldwide offices You can also log onto the online help section of the Crestron website to ask questions about Crestron products First time users will need to establish a user account to fully b...

Page 39: ...hscreen display and overlay components are covered for 90 days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRES...

Page 40: ...Crestron Electronics Inc Operations Guide DOC 6262A 15 Volvo Drive Rockleigh NJ 07647 2010201 Tel 888 CRESTRON 03 05 Fax 201 767 7576 Specifications subject to www crestron com change without notice...

Reviews: