background image

©  CRESTO  Smartline  X  |  EDITION  001/2017-­10-­02  |  UK  version  (Master)

  

  

|  11  

  

  

6.  MAINTENANCE,  STORAGE  AND  PERIODIC  INSPECTION  

6.1  Storage  

The  

Smartline  X  

must  not  be  exposed  to  chemicals  or  stored  together  with  chemicals.  It  

shall  be  protected  from  strong  heat,  UV  light,  light,  high  humidity,  sharp  edges  or  other  
influences  that  can  affect  the  security  of  the  equipment.  

  

6.2  Maintenance  

As  the  

Smartline  X  

is  designed  for  single  use  only,  there  is  no  need  for  maintenance.    

If  there  are  concerns  about  humidity  in  the  bag  or  possible  damage  to  the  equipment,  it  
must  be  inspected  according  to  section  4.  All  reparations  or  alterations  have  to  be  
done  by  a  body  approved  by  the  manufacturer.  

Warning

:  If  the  equipment  becomes  wet,  it  is  allowed  to  dry  naturally,  not  by  direct  

heat  or  UV-­light.      

  

6.3  Transport  

During  transport  the  

Smartline  X  

must  not  be  exposed  to  sharp  items,  chemicals,  UV-­  

light,  or  other  influences  that  may  cause  damage.  It  must  also  be  protected  against  falls,  
crush  and  shock  damages.  

  

6.4  Inspection  of  equipment  

Personal  inspection  before  use  is  described  in  section  4.  

The  

Smartline  X  

has  to  undergo  periodic  inspection  by  a  competent  person  at  least  

once  every  12  months.  This  person  must  be  familiar  with  inspecting  all  the  components  
in  the  set,  and  must  know  in  detail  how  the  set  works.  

The  set  must  always  be  opened  during  periodic  inspection.  Repairs  and  replacement  of  
parts  can  only  be  done  by  

CRESTO  AB

.  Sweden  or  a  body  approved  by  

CRESTO  

Warning

:  The  need  for  regular  periodic  examinations,  and  that  the  safety  of  users  depends  

upon  the  continued  efficiency  and  durability  of  the  equipment  

The  equipment  log  on  the  last  page  must  be  updated  with  all  periodic  inspections,  
service  and  repairs  and  other  matters  concerning  the  safe  use  of  the  equipment,  if  the  

CRESTO  INSPECTOR  

data  base  is  not  utilized.  

The  Smartline  X  is  equipped  with  a  RIFD  chip  connecting  it  to  the  

CRESTO  

INSPECTOR  

for  easy  track  and  trace  of  units  and  service.  

The  RFID  is  located  in  the  marking  label  see  section  8.  

  

6.4.1  Inspection  criteria  

  

  

Aborber:  

check  for  deployment,  material  and  stitching  for  damage  including  cuts,  nicks,  

abrasion,  fraying,  discolorations,  heat  or  chemical  damage  and  moisture

  

  

Connectors:

  gate  function,  abrasion,  deformation,  corrosion,  cracks  and  nicks

  

  

Device:

  seal  is  intact,  abrasion,  deformation,  cracks,  nicks  and  corrosion

  

  

Rope:

  for  loops  in  the  material,  damage,  cuts,  tears,  signs  of  chemicals  and  UV  

degradations,  discolorations,  heat  damage,  and  moisture

  

  

Marking:

  Legibility  of  marking,  serial  no.,  date  of  manufacturing        

  

Summary of Contents for RESQ Smartline X

Page 1: ...EN I N S T R U C T I O N S F O R U S E I N S P E C T I O N C A R D F O R Smartline X EN341 CLASS D...

Page 2: ......

Page 3: ...Smartline X CE NOTIFIED BODY 0200 REVISION NUMBER 001 2017 10 02 EN...

Page 4: ......

Page 5: ...d this user manual SMARTLINE XTM Section Contents Page 1 Safety instructions 2 2 Introduction 4 3 Complete Kit 4 4 Inspection of equipment before use 5 5 Using the Smartline X 5 6 Maintenance storage...

Page 6: ...nding goods are prohibited and illegal and will terminate all liable and legal obligations between the user and the manufacturer 1 3 Service inspection repair and training must be carried out in accor...

Page 7: ...than normal emergency use would The producer does not recommend the use of emergency devices for training use This is due to the fact that the technical specification in production is optimised to em...

Page 8: ...roved body for inspection and replacement of the line The Smartline X may be supplied with different line lengths as specified on the equipment The Smartline X is a complete system which consists of t...

Page 9: ...CRESTO Smartline X EDITION 001 2017 10 02 UK version Master 5 Fig 1 1 5 2 8 7 3 4...

Page 10: ......

Page 11: ...r equipment that might be in use If you have questions about the use of this equipment please contact CRESTO AB 5 2 Restrictions on use The Smartline X must ONLY BE USED ONCE After use the Smartline X...

Page 12: ...depending on speed and load the descender will get hot and must not be touched other places than on the handle and the line The use of heavy duty working gloves is mandatory to avoid injuries on hands...

Page 13: ...oad of 12 kN If the anchor sling is placed around a vertical construction detach the sling and place it twice around the pole and through itself again Then attach the karabiner as shown in fig 1 B Ens...

Page 14: ...id exposing the equipment to dynamic loads 5 Ensure that the descent is not in conflict with moveable machinery obstacles or live cable The line must not lie over sharp edges It is advisable to take t...

Page 15: ...ay as shown in fig 3 C It is important to always keep one hand on the line to control the descent fig 3 B fig 3 C 8 During long descents and heavy loads a lot of heat will be induced There might even...

Page 16: ...osition yourself in a safe and appropriate position next to the casualty 3 Open the bag and access the Smartline X 4 Detach the karabiner from the anchor sling Place the anchor sling around a structur...

Page 17: ...pment so that the person is lowered until his weight is fully onto the Smartline X Then the other fall protection equipment can be removed and the descent started Person hanging in none adjustable fal...

Page 18: ...moving the handle downwards or by releasing it Increase or decrease friction by moving the line into the narrow part of the slot or away as shown in Fig 3 B and 3 C It is important to always keep one...

Page 19: ...very 12 months This person must be familiar with inspecting all the components in the set and must know in detail how the set works The set must always be opened during periodic inspection Repairs and...

Page 20: ...etal components has a maximum lifetime of 10 Years If in doubt of the safe function of a component the Smartline X shall all be withdrawn from service All maintenance or alterations have to be done by...

Page 21: ...d of 12 kN The karabiner may also connect directly to a part of the structure as long as this part supports a load of 12 kN and does not cause unintended strain on the karabiner If special designed an...

Page 22: ...ication A S 10 INSPECTION AND USER LOG Company Product Descender device class D User Reference Marking CE 0200 Length Date of Purchase Serial No Date of manufacturing Date first put into use Inspectio...

Page 23: ...CRESTO Smartline X EDITION 001 2017 10 02 UK version Master 17 CRESTO AB L GATAN 3 SE 302 63 HALMSTAD SWEDEN TEL 46 0 10 45 47 500 office cresto se www cresto se...