Operation and Maintenance Manual for F-100 Cleaning System
F-100 Manual Rev H
Non-Flammable
8
AFTER SOLVENT HAS BEEN DRAINED
4. Place the main power disconnect in the OFF position.
Figure5: Main Disconnect
EMERGENCY SHUTDOWN
1. Press the
CONTROL POWER OFF/ EMERGENCY STOP
button on the main enclosure.
Figure 6: Control Power Off/E-Stop Buttons
2. The cleaning system will
automatically
shut off the heating system and allow the sump to
cool.
NOTE: This will not kill the power to the cooling system as it is a greater safety risk to
not provide vapor containment. DO NOT shut off the main power until the solvent is at
room temperature. Turning off the main power before the solvent is at room
temperature will shut down the compressor and cause excess solvent loss, and result
in a longer cool down time.