Forward Technology – a Crest Group Company
Operation and Maintenance Manual for F-100 Cleaning System
F-100 Manual Rev H
Non-Flammable
9
FILLING AND DRAINING SOLVENT
WARNING: Observe all safety precautions when transferring solvent in and out of the
machine.
FILLING
There are two options for filling the system:
1. Add chemical directly to the F-100 by pouring or siphoning (recommended) it into the
wash sump. Allow the chemical to roll over the weir into the boil until it is approximately
1 to 2 inches below the weir (max) or above the float switch (minimum).
2. The second is outlined below using the bulkhead connections & a transfer pump (not
included).
Filling the F-100 using bulkhead connections.
1.
Hook a fill hose & pump (not included) to the wash sump bulkhead connection.
Figure 7: Outside Bulkhead Figure 8: Inside Bulkhead
2.
Open the wash sump ball valve connected to the wash sump.
Figure 9: Tank Ball Valves
3.
Start the pump this should begin to filling the system; when the wash sump is full it will
cascade into the boil sump. Allow the boil sump to fill until it is approximately 1 to 2
inches below the weir (max) or above the float switch (minimum). Shut off the fill/drain
pump & shut off the wash sump valve.
WASH SUMP
OPEN to Fill
BOIL SUMP
Leave Closed