background image

cressi.com

ALARM OF THE SUM OF THE DIVING TIME AND THE SURFACE TIME FOR DYNAMIC PROGRAM.

The alarm of the sum of the diving time and the surface time for the DYNAMIC program has the main 
purpose of supporting the diver who practice repeated dives in the pool or who needs a precise cadence 
practising the activity in the sea. In this way, he will have a time parameter available to speed or decrease 
his gaits or to repeat the surface-diving cycle. The computer must be set with the DYNAMIC program. To 
set the alarm scroll with UP or DOWN buttons until the ALARMS menu. Enter the menu by pressing the 
MODE button. The numbers in the top left of the display below the MAX indicator will flash. Press the 
MODE button again. The display will show only the highlighted information and the minutes indicator will 
flash. Set the desired value by pressing the UP or DOWN buttons. Confirm the set value by pressing the 
Mode button until hearing an acoustic signal of confirmation. The second figures will flash.
Set the desired value by pressing the UP or DOWN buttons. Confirm the set value by holding down the 
Mode button for a few seconds until hearing an acoustic signal to confirm the exit from the menu. 
Alternatively, after some seconds the buttons are pressed, the computer will automatically register the 
changes carried out at that moment by issuing an acoustic signal to return then to the main screen.
Once the alarm has been set, the display will indicate that the sum of diving and surface times set has 
elapsed by making it flash and, if the audible alarms have been set, an acoustic signal will also sound.

SURFACE TIME ALARM FOR 

DYNAMIC AND STATIC PROGRAMS.

The alarm of the surface time for STATIC and DYNAMIC programs has the main purpose of supporting the 
diver who performs, for example, the tanks or repeated dives in the pool. In this way, he will have a time 
parameter available to speed or decrease his gaits or to recover the energy properly keeping certain 
benefits.
The computer must be set with the DYNAMIC or STATIC program.

DYNAMIC: 

To set the alarm scroll with UP or DOWN buttons until the ALARMS menu. Enter the menu by 

pressing the MODE button. The numbers in the top left of the display below the MAX indicator will flash. 
Press the UP button once. The numbers in the top right below the word SURF.T MAX will flash. Press the 
MODE button again. The display will show only the highlighted information and the minutes indicator will 
flash. Set the desired value by pressing the UP or DOWN buttons. Confirm the set value by pressing the 
Mode button until hearing an acoustic signal of confirmation. The second figures will flash. Set the desired 
value by pressing the UP or DOWN buttons. Confirm the set value by holding down the Mode button for a 
few seconds until hearing an acoustic signal to confirm the exit from the menu. Alternatively, after some 
seconds the buttons are pressed, the computer will automatically register the changes carried out at that 
moment by issuing an acoustic signal to return then to the main screen.
Once the alarm has been set, the display will indicate that the surface time set has elapsed by making it 
flash and, if the audible alarms have been set, an acoustic signal will also sound.

STATIC: 

To set the alarm scroll with UP or DOWN buttons until the ALARMS menu. Enter the menu by 

pressing the MODE button. The numbers in the top right below the word SURF.T MAX will flash. Press the 
MODE button again. The display will show only the highlighted information and the minutes indicator will 
flash. Set the desired value by pressing the UP or DOWN buttons. Confirm the set value by pressing the 
Mode button until hearing an acoustic signal of confirmation. The second figures will flash. Set the desired 
value by pressing the UP or DOWN buttons. Confirm the set value by holding down the Mode button for a 
few seconds until hearing an acoustic signal to confirm the exit from the menu. Alternatively, after some 
seconds the buttons are pressed, the computer will automatically register the changes carried out at that 
moment by issuing an acoustic signal to return then to the main screen.
Once the alarm has been set, the display will indicate that the surface time set has elapsed by making it 
flash and, if the audible alarms have been set, an acoustic signal will also sound.

ALARM OF THE SUM OF THE DIVING TIME AND THE SURFACE TIME FOR DYNAMIC PROGRAM

AUTOMATIC 
RETURN OR
 WITH LONG 

MODE BUTTON

BEEP

AUTOMATIC 
RETURN OR
 WITH LONG 

MODE BUTTON

BEEP

LONG

LONG

ALARMS: SURFACE TIME  ALARM FOR DYNAMIC AND STATIC PROGRAMS

AUTOMATIC 
RETURN OR
 WITH LONG 

MODE BUTTON

BEEP

AUTOMATIC 
RETURN OR
 WITH LONG 

MODE BUTTON

BEEP

DYNAMIC:

STATIC:

17

Summary of Contents for DRAKE

Page 1: ...cressi com DRAKE INSTRUCTION MANUAL cressi com...

Page 2: ...REE and PRO programs setting of acoustic alarms and sea and fresh water page 15 Automatic lighting and Depth to Step alarm for PRO program page 16 Diving time and Surface time sum alarm for DYNAMIC pr...

Page 3: ...n aid to free diving for people carefully prepared to the risks this activity entails It must be used then only and exclusively when you have a complete theoretical and practical training on the techn...

Page 4: ...ing has the STATIC program and the dynamic diving has the DYNAMIC program Additionally the device may be set by the user for either metric m C or feet system ft F The Drake underwater watch computer c...

Page 5: ...use the loss of TIME and DATE CHRONOGRAPH To access the chronograph press the UP or DOWN push button up to the CHRONO menu down in the display then press MODE CHRONO disappear to give way to the count...

Page 6: ...velling it is necessary to store data of the computer using the time zone of the place but at the same time it is possible to also see the time at the place of origin This need is strongly felt especi...

Page 7: ...DE button and then the message DIVE appears on the display and then after releasing it the PRE DIVE screen of the set program Free Pro Dynamic and Static In the second mode it is necessary to scroll t...

Page 8: ...ber of the last session 2 MODE S It allows choosing the free diving mode that you want The computer has four modes FREE PRO DYNAMIC and STATIC 3 ALARMS The ALARMS menu allows setting different alarms...

Page 9: ...ted to free diving without the need to conduct a comprehensive analysis of its performance Very suitable for underwater fishermen Perfect for snorkelling and for those who practice intensively the dis...

Page 10: ...age speed Scrolling with UP or DOWN buttons at the centre total diving time and total surface time Scrolling with UP or DOWN buttons in the complete display average data from top left average time rat...

Page 11: ...diaphragmatic contractions Always visible Acoustic alarms icon activated REPS icon activated How to use the STATIC program Once in the program it must be operated manually by pressing the Mode button...

Page 12: ...buttons downward total training and session time time and reset function Always visible Sea water or fresh water setting icon Acoustic alarms icon activated How to use the DYNAMIC program Once in the...

Page 13: ...ine It is a disease that is known since the 40s and that affected the Polynesian pearl divers the term TARAVANA means madness The cause can be summed up in an intense and excessive activity of diving...

Page 14: ...the message DEPTH1 will appear Confirm by pressing the MODE button The message DEPTH2 will appear Set the desired value by pressing the UP or DOWN buttons And so on up to the third alarm Confirm the...

Page 15: ...utton again The flashing words ON or OFF will appear on the display Change the words using the UP or DOWN button but remember that in case of ON the alarms will be activated while in case of OFF the a...

Page 16: ...ery time a predetermined value in metres is passed For example By setting the STEP alarm to 5 we will be notified whenever the depth reaches a multiple of 5 That is 5 10 15 20 etc To set the STEP alar...

Page 17: ...flash Press the UP button once The numbers in the top right below the word SURF T MAX will flash Press the MODE button again The display will show only the highlighted information and the minutes indi...

Page 18: ...ain The display will show only the highlighted information and the minutes indicator will flash Set the desired value by pressing the UP or DOWN buttons Confirm the set value by pressing the Mode butt...

Page 19: ...arked with the words DIVE MAX this value must flash Enter with the MODE button and change the value with the UP or DOWN buttons Confirm the set value by holding down the Mode button for a few seconds...

Page 20: ...ing an acoustic signal to confirm the exit from the menu Alternatively after the last time the buttons are pressed the computer will automatically register the changes by issuing an acoustic signal to...

Page 21: ...ings stored they must be imported with the load function IMPORT OF ALARMS SETTINGS To import a previously saved alarm setting it is necessary to scroll with the UP and DOWN buttons up to the ALARMS me...

Page 22: ...press the UP or DOWN button to move forwards or backwards to the desired one The LOG BOOK has four screens per session To display the second screen of the session once desired session number has been...

Page 23: ...s necessary to have the appropriate hardware adapter sold separately The Personal Computer must be equipped with Windows Mac operating system and video resolution 800x600 or higher recommended To conn...

Page 24: ...se and we will have the ability to store multiple sessions and individual dives In contrast with short times we will have a greater accuracy of the diving profiles and a greater accuracy of the data p...

Page 25: ...or water filtration due to incorrect battery replacement will void the warranty 25 TECHNICAL SPECIFICATIONS Sizes and Weight Diameter 48 mm Height 15 mm Weight 135 g Depth sensor Sea or fresh water se...

Page 26: ...or replacement of the Product Cressi or a Cressi authorised service centre can use new as new or repaired products or parts Exceptions and limitations This limited warranty does not cover 1 a product...

Reviews: